Published June 20, 2024 | Version 1.0

ENDGAME - Laboratory Experiment 2023-02-21 Exp. 017 - High Speed Camera data

Description

Shock-tube experiments in combination with high speed Schlieren shadow photography. 

The shocktube setup consists of a high-pressure reservoir connected with a cylindrical tube through a diaphragm pulse valve which allows a fast release of pressurized gas into the ambient pressure tube. The high-pressure reservoir is filled with compressed air at a given overpressure with respect to ambient pressure (up to 8 bar). The pipe was either empty (i.e. with air at ambient conditions) or filled with a given amount of fluids (water or viscous fluid) or small particles. We adopted pipes with different inner diameters (3 and 4 cm) and different lengths (30 and 80 cm). Images were collected at a frame rate of 30000 fps.

When the valve is open, a jet flow is produced, with shock and acoustic waves propagating in the atmosphere, which become visible due to the high speed Schlieren shadow photography.

Files

ENDGAME_LabExp_HighSpeedCamera_20230221_017.zip

Files (1.0 GB)

Name Size
md5:1fe74af74461f29ac4939c975b9ab7db
1.0 GB Preview Download

Additional details

Funding

European Commission
ENDGAME - laboratory Experiments, Numerical moDellinG and field observAtions of basaltic Magma fragmEntation 101025887