Published February 28, 2023 | Version v1
Report Open

D2.2 – Characterization of PFAS and chlorinated solvent contamination in two aquifers in Spain

  • 1. IDAEA-CSIC - Spanish Council for Scientific Research
  • 2. IDAEA-CSIC
  • 3. ROR icon Institute of Environmental Assessment and Water Research
  • 4. ROR icon Barcelona Media
  • 5. ROR icon Universitat de Barcelona
  • 6. Fundació EURECAT
  • 7. ROR icon EURECAT Centre Tecnològic de Catalunya

Description

The aim of this deliverable is the description and characterisation of the Case Study #7 foreseen in PROMISCES. The investigation has been conducted in 2 sites, the originally considered site contaminated due to diffuse pollution from a waste treatment facility and other industrial sources (Site 1), and a second one likely to be contaminated with PFAS due to fire-fighting training practices (Site 2). 

As a result, the aquifer remediation treatments to be implemented in PROMISCES focus on the compounds (VOCs and PFAS) identified as most relevant in the present deliverable as well as in Site 2 for the field remediation testing.

Files

PROMISCES D2.2 Characterization of PFAS.. in PROMISCES WEBPAGE.pdf

Files (1.6 MB)

Additional details

Funding

European Commission
PROMISCES - Preventing Recalcitrant Organic Mobile Industrial chemicalS for Circular Economy in the Soil-sediment-water system 101036449