Published December 20, 2022 | Version 1
Technical note Open

Mitochondrial enrichment followed by Affinity Purification couple to Mass Spectrometry (AP-MS)

  • 1. CEMM - Research Center for Molecular Medicine. Vienna, AT.

Description

Due to their dual membrane composition and high hydrophobicity, mitochondrial SLCs are not ideal candidates for the mild lysis condition we standardly used in RESOLUTE WP2 AP-MS. We, therefore, use an adapted protocol (modified from Frezza et al.) for the study and definition of protein-protein interaction network of mitochondrial SLCs.

Files

SP000H-F_AP-MS_Mito_v2.pdf

Files (277.6 kB)

Name Size Download all
md5:25828dc10ffcdabf19a6b12a1f53350d
277.6 kB Preview Download

Additional details

Funding

European Commission
ReSOLUTE - Research empowerment on solute carriers (ReSOLUTE) 777372