Published October 13, 2022
| Version v1
Dataset
Open
Data for "High-accuracy determination of Paul-trap stability parameters for electric-quadrupole-shift prediction", J. Appl. Phys. 132, 124401 (2022)
Authors/Creators
- 1. National Metrology Institute VTT MIKES, VTT Technical Research Centre of Finland Ltd, Espoo, Finland
Description
Data required to reproduce the key results in: "High-accuracy determination of Paul-trap stability parameters for electric-quadrupole-shift prediction", J. Appl. Phys. 132, 124401 (2022). https://doi.org/10.1063/5.0106633
- The file "sec_freq.dat" contains measured secular frequencies, the rf frequency, the applied bias voltages, and the MJD of the measurement:
- Figures 4-5 use rows 31-33 of this data.
- Figure 6 uses all data corresponding to -1.1e-3 < ax < -0.6e-3.
- Figure 7(a) uses all the data.
- The file "data2021-12-21_MJD.txt" contains the secular frequency data used to derive Eq. (16) and plot Figure 8.
- The file "RF_monitor_rectifier_1d.txt" contains the rectified monitor voltage used in Figure 8.
- The file "Temperature_108_1d.txt" contains the helical-resonator temperature used in Figure 8.
- The file "Fig9_EQS.dat" contains the measured electric quadrupole shift (EQS) used for Figure 9.
- The file "interleavedEQS.dat" contains the data from the interleaved EQS measurement used to determine a lower value of 1070 for the cancellation factor.
Notes
Files
data2021-12-21_MJD.txt
Files
(425.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:02ece8926a86bf0608667addbddcf33e
|
17.8 kB | Preview Download |
|
md5:263b35e664c539d4d2f9ad9478df322a
|
207.2 kB | Download |
|
md5:598db85600194d46b0b7543376784ee3
|
130.1 kB | Download |
|
md5:1f37f71186a24427fc3401225cc44153
|
35.8 kB | Preview Download |
|
md5:6059e9106ce352021d6f0b0ba49b720a
|
17.6 kB | Download |
|
md5:0308cef700f67f9f4a6767f0633b86c5
|
16.6 kB | Preview Download |
Additional details
Related works
- Is source of
- Journal article: 10.1063/5.0106633 (DOI)
- Preprint: 10.48550/arXiv.2209.02290 (DOI)