Hyperspectral X-ray CT datasets of an aluminium phantom containing three metal-based powders
Creators
- 1. University of Manchester
Description
General Data description:
This is a set of two hyperspectral (energy-resolved) X-ray CT projection datasets of a multi-phase phantom. It was acquired in a custom-built, laboratory micro-CT scanner with an energy-sensitive HEXITEC detector in the Henry Moseley X-ray Imaging Facility at The University of Manchester.
The following data contains all the files necessary for reconstruction, following two hyperspectral scans of a metal, multi-phase phantom. The phantom consists of an external aluminium cylinder, with three holes, each filled with a different metal-based powder (CeO2, ZnO, Fe). Each powder provides a unique attenuation signal, with CeO2 in particular producing a distinct spectral marker which can be measured by an energy-sensitive detector. Two identical scans were acquired, with only the exposure time per projection changed.
Note: Zenodo Version 2 of this dataset contains the incorrect version of the 180s, 180 projection phantom dataset, if wishing to analyse the dataset used in the associated hyperspectral paper. This version (Version 3) contains the correct dataset from the paper.
File descriptions:
Contained is an image (.jpg) of the sample, along with five MATLAB (.mat) data files, as well as a single text (.txt) file. Where necessary, the files have been named to match the dataset they belong to, based on the different exposure times used for each dataset.
Phantom_design_measurements.jpg contains a photograph of the physical phantom, combined with a diagram showing full sample measurements.
Powder_phantom_scan_geometry.txt gives a breakdown of the full sample and detector geometry used when acquiring the raw projections for both scans.
Powder_phantom_30s_30Proj_sinogram.mat contains the 4D sinogram constructed following flatfield normalisation of the raw projection data, where an exposure time of 30 s was used for each projection. The 4D array contains the total number of energy channels acquired during scanning, followed by vertical and horizontal pixel number, and finally total projections angles acquired during scanning. The total number of channels in the file is 200.
Powder_phantom_180s_180Proj_sinogram.mat is the 4D sinogram for the dataset, when exposure times of 180 s were used for each projection, following flatfield normalisation. A discontinuity occurs at projection 137 due to an interruption in the scan procedure. The total number of channels in the file is 200.
Energy_axis.mat provides a direct conversion between the energy channels, and the energies (in keV) that they correspond to, following a calibration procedure prior to scanning. This is the same for both datasets.
FF_30s.mat contains the 4D flatfield data acquired when no sample was present, in the case of 30 s exposure times. This data was used to normalise the projection datasets, as the sinogram was constructed. The first 200 channels are included.
FF_180s.mat contains the 4D flatfield data for the dataset where 180 s exposure times were used. The first 200 channels are included.
Files
Phantom_design_measurements.JPG
Files
(5.5 GB)
Name | Size | Download all |
---|---|---|
md5:799faf8453de729ade6fa10683b9a361
|
1.5 kB | Download |
md5:13695a5598752e64a015c64a705a4308
|
4.5 MB | Download |
md5:6c0254084adfda8279059477218f1727
|
3.8 MB | Download |
md5:c7a4ba8bc15ae33ab42951479f0c6fc7
|
39.4 kB | Preview Download |
md5:7ab3ce0453378c3bc67b46b4d1b5aea6
|
1.6 GB | Download |
md5:20f29c089fa10ba4871b92e34cddf269
|
3.2 GB | Download |
md5:f093b7099baa7f7f2a9d0e64ae7b483b
|
273.3 MB | Download |
md5:6f27a67d9fa9063b8025bb7cd3f2a581
|
461.9 MB | Download |
md5:6c450b3944c395acd8b36dbf41f6ee7d
|
326 Bytes | Preview Download |
Additional details
Related works
- Is cited by
- Journal article: 10.1038/s41598-021-00146-4 (DOI)
Funding
- UK Research and Innovation
- Next Generation Multi-Dimensional X-Ray Imaging EP/M010619/1
- UK Research and Innovation
- A Reconstruction Toolkit for Multichannel CT EP/P02226X/1
- UK Research and Innovation
- Tomographic Imaging EP/M022498/1