Published June 30, 2020 | Version v1
Journal article Open

Experimental work on the Low Reynolds Number Behaviour of 2-Hole Offset Probes

  • 1. Tech student, Department of Mechanical Engineering, Lingaya's Vidyapeeth, Faridabad, Haryana, India.
  • 2. Professor & Head, Department of Mechanical Engineering, Lingaya's Vidyapeeth, Faridabad, Haryana, India
  • 1. Publisher

Description

Whenever a dusty or slurry air passes through the Ltype pitot tube its impurities struck at 900 bend, resulting in the partially choking of the air flow through this device. And eventually its accuracy is decreased with the passage of time. Alternatively, such type of obstruction of the air flow can be avoided by using Stype pitot tube. Keeping this in mind, in the present work we had used S-type pitot tube of diameters ranging from 1.23 mm to 9.54 mm to test against the standard (L-type) pitot tube to control the accuracy of S-type pitot tube co-efficient. An experimental work has been carried out in a simulated wind tunnel environment. The results of the present work showed that there a slight dip over a velocity range of 3 to 14 m/s. Further, it is observed that for higher Reynolds numbers or at higher velocities of the air (more than 14 m/s) the co-efficient performance of S-pitot tube is found almost constant.

Files

E9669069520.pdf

Files (1.1 MB)

Name Size Download all
md5:c7053a073f9c7dc7099c6258ea33b3ab
1.1 MB Preview Download

Additional details

Related works

Is cited by
Journal article: 2249-8958 (ISSN)

Subjects

ISSN
2249-8958
Retrieval Number
E9669069520/2020┬ęBEIESP