Laboratory comparison of low-cost particulate matter sensors to measure transient events of pollution - Dataset
Creators
- 1. University of Southampton
- 2. Aarhus University
- 3. University of Copenhagen
- 4. National Oceanography Centre, Southampton
Description
This repository contains the data associated with the paper: Laboratory comparison of low-cost particulate matter sensors to measure transient events of pollution.
Bulot, F.M.J.; Russell, H.S.; Rezaei, M.; Johnson, M.S.; Ossont, S.J.J.; Morris, A.K.R.; Basford, P.J.; Easton, N.H.C.; Foster, G.L.; Loxham, M.; Cox, S.J. Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution. Sensors 2020, 20, 2219.
https://doi.org/10.3390/s20082219
It contains:
- DHT22.csv measurements from the DHT22 humidity and temperature sensor
- dusttrak.csv measurements from the DustTrak
- ops.csv measurements from the OPS TSI 3330
- sensors.csv measurement from the low-cost PM sensors
- sensors_blank.csv measurements from the low-cost PM sensors during the blank test
sensors_blank.csv contains the following variables:
- Bin1 to Bin15: particle numbers for different bin sizes reported by the Alphasense OPCR1, as defined by its user's manual available here https://www.alphasense.com/products/optical-particle-counter/
- SamplingPeriod: sampling period of the Alphasense OPCR1 in seconds
- SFR: sampling flow rate of the Alphasense OPCR1 in ml/s
- PM1, PM25, PM4, PM10: PM concentrations reported by the sensors in ug/m3.
- gr03um to gr100um: particle number concentrations for different bin sizes for the Plantower PMS5003, in particle per 100ml, as defined by its user's manual https://aqicn.org/air/view/sensor/spec/pms5003-manual_v2-3
- n05 to n10: particle number concentrations for different bin sizes for the Sensirion SPS30, in particles per cm3, as defined by its user's manual: https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/9.6_Particulate_Matter/Datasheets/Sensirion_PM_Sensors_Datasheet_SPS30.pdf
- humidity and temperature: relative humidity (%) and temperature (Celsius) recorded by the SHT35 sensors
- sensor: sensor identifier
- site: name of the air quality monitor containing the sensors
- exp: name of the experiment considered
- source: source of PM used
- variation: peak or stable concentration
- date: date and time of the experiment
Files
DHT22.csv
Files
(159.8 MB)
Name | Size | Download all |
---|---|---|
md5:b836203b82fc76ebc089d152f3ee474d
|
223.0 kB | Preview Download |
md5:36f0ad852eaa4a61cf6c16bc29d93531
|
94.6 kB | Preview Download |
md5:8c67866671b3424ab29d2ecf8f7821f3
|
173.9 kB | Preview Download |
md5:31a24cffc72ca9b6c9237ab7c2301fa0
|
210.8 kB | Preview Download |
md5:63f7ffc5d36a0672592f122a7cd07467
|
53.0 MB | Preview Download |
md5:55eae8f364628832825b5179c7071744
|
106.1 MB | Preview Download |
Additional details
Funding
- The Biological Effects of Shipping-Related Particulate Matter Air Pollution BB/P011365/1
- UK Research and Innovation
- Next Generation Unmanned Systems Science (NEXUSS) NE/N012070/1
- UK Research and Innovation