Published November 6, 2026 | Version 2.0
Dataset Embargoed

Data from Radiometer (RAD) measurements at Bristol – Queens Building Engineering (BRENGI) from 2024-07-29 to 2025-04-02 [L0]

  • 1. ROR icon University of Freiburg
  • 2. ROR icon University of Reading
  • 3. ROR icon University of Bristol

Description

Combined and unfiltered logger data from radiometer measurements using a sun tracker at Bristol – Queens Building Engineering (BRENGI) during the ASSURE / urbisphere / UrbanAIR Bristol Campaign from 2024-07-29 13:20 to 2025-04-02 10:20 UTC with a temporal resolution of 1 min. Station Bristol – Queens Building Engineering (BRENGI) was operated on a roof of the University of Bristol's Queens Building at 51.456611°N / 2.0613882°W.

Radiometer measurements taken at BRENGI are:

  • Global (solar) hemispherical irradiance (GHI) with a ventilated Kipp&Zonen CM21 pyranometer
  • Diffuse (solar) hemispherical irradiance (DHI) with a ventilated and shaded Kipp&Zonen CM21 pyranometer
  • Direct (solar) Normalized irradiance (DNI) with a Kipp&Zonen CHP1 pyrheliometer
  • Longwave hemispherical irradiance (LHI) with a ventilated and shaded Kipp&Zonen CG4 pyrgeometer

The values in this dataset are calibrated using manufacturer calibrations for all instruments and no further quality controlls or gap filling procedures have been applied. For quality controlled and calibrated data use L1 data and higher instead. 

The two L0 datafiles (RAW_1min, MET_1min) combine all individual (uncalibrated voltage and manufacturer calibrated) logger files (automatic transfer, manual download) with a consistent and consecutive time axis. Missing data is filled with -9999. Each data file is structured with time steps as rows and parameters as  column in comma-separated csv format. The columns contain readings from all four radiometers and a co-located all-in-one weather station (Campbell Scientific ClimaVue50) providing barometric pressure, air temperature, humdity, wind, precipitation and also a back-up solar irradiance (low quality, photodiode). Files have 4 header lines following the Campbell Scientific Inc. TOA5 file definition. 

File "BRENGI-MET_1min-202407290000_202504030000_UTC.csv" contains the manufacturer calibrated physical values:

Column descriptions:

  • TIMESTAMP: Time / Date of the end of the aggregation interval in UTC in format YYYY-MM-DD hh:mm:ss
  • RECORD: Continuous internal record number
  • MET_CHP1_DNI_Wm2_Avg: Average direct normal irradiance in W/m2 measured with a pyrheliometer (Kipp & Zonen CHP1)
  • MET_CHP1_DNI_Wm2_Std: Standard deviation of direct normal irradiance in W/m2 measured with a pyrheliometer (Kipp & Zonen CHP1)
  • MET_CM21_GHI_Wm2_Avg: Average global (solar) hemispherical irradiance in W/m2 measured with an actively ventilated thermopile pyranometer (Kipp & Zonen CM21)
  • MET_CM21_GHI_Wm2_Std: Standard deviation of global (solar) hemispherical irradiance in W/m2 measured with an actively ventilated thermopile pyranometer (Kipp & Zonen CM21)
  • MET_CM21_DHI_Wm2_Avg: Average diffuse (solar) irradiance in W/m2 measured with an actively ventilated thermopile pyranometer shaded by shading ball (Kipp & Zonen CM21)
  • MET_CM21_DHI_Wm2_Std: Standard deviation of diffuse (solar) irradiance in W/m2 measured with an actively ventilated thermopile pyranometer shaded by shading ball (Kipp & Zonen CM21)
  • MET_CG4_LHI_Wm2_Avg: Average longwave hemispherical irradiance in W/m2 measured with an actively ventilated thermopile pyrgeometer (Kipp & Zonen CG4)
  • MET_CG4_LHI_Wm2_Std: Standard deviation of longwave hemispherical irradiance in W/m2 measured with an actively ventilated thermopile pyrgeometer (Kipp & Zonen CG4)
  • MET_CV50_PressureActual_hPa_Avg: Actual pressure in hPa (not reduced to sea level) measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_Wind_ms_Avg: Wind velocity scalar mean in m/s measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_WindGustMax_ms_Max: Wind velocity maximum in m/s measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_Wind_ms_Vec: Wind velocity vector mean in m/s measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_WindDirection_deg_Vec: Wind direction in ° measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_AirTemperature_degC_Avg: Air temperature in °C measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_RelHumidity_percent_Avg: Relative humidity in % measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_DewPoint_degC_Avg: Dew point in °C calculated based on air temperature and relative humidity measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_VapourPressure_hPa_Avg: Vapour pressure in hPa calculated based on air temperature and relative humidity measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_VapPressDeficit_hPa_Avg: Vapour pressure deficit in hPa calculated based on air temperature and relative humidity measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_MixingRatio_gKg_Avg: Mixing ratio in g/kg calculated based on air temperature and relative humidity measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_GHI_Wm2_Avg: Average global (solar) hemispherical irradiance in W/m2 measured with a photodiode [low quality] pyranometer in the all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_Precipitation_mm_Tot: Precipitation measured with an droplet counter in the all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_LtngStrikes_cnt_Tot: Number of lightning strikes measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • MET_CV50_LtngDist_km_Avg: Average distance of lightning strikes measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)

Missing data are shown with -9999. Missing data and data gaps are summarized in "BRENGI-MET_1min-202407290000_202504030000_UTC_missing_data_report.txt"

File "BRENGI-RAW_1min-202407290000_202504030000_UTC.csv" contains the raw voltage and auxilliary measurements such as pyrgeometer temperature:

Column descriptions:

  • TIMESTAMP: Time / Date of the end of the aggregation interval in UTC in format YYYY-MM-DD hh:mm:ss
  • RECORD: Continuous internal record number
  • RAW_Cr1000_Voltage_V_Min: Minimum battery voltage measured on the CR1000X data logger
  • RAW_Cr1000_PanelTemp_degC_Avg: Average panel temperature on the CR1000X data logger
  • RAW_CHP1_DNI_Signal_mV_Avg: Average voltage signal of the pyrheliometer (Kipp & Zonen CHP1)
  • RAW_CHP1_DNI_Signal_mV_Min: Min voltage signal of the pyrheliometer (Kipp & Zonen CHP1)
  • RAW_CHP1_DNI_Signal_mV_Max: Max voltage signal the pyrheliometer (Kipp & Zonen CHP1)
  • RAW_CHP1_DNI_Signal_mV_Std: Standard deviation the pyrheliometer (Kipp & Zonen CHP1)
  • RAW_CM21_GHI_Signal_mV_Avg: Average voltage signal of the ventilated thermopile pyranometer for global hemispherical irradiance (Kipp & Zonen CM21)
  • RAW_CM21_GHI_Signal_mV_Min: Min voltage signal of the ventilated thermopile pyranometer for global hemispherical irradiance (Kipp & Zonen CM21)
  • RAW_CM21_GHI_Signal_mV_Max: Max voltage signal of the ventilated thermopile pyranometer for global hemispherical irradiance (Kipp & Zonen CM21)
  • RAW_CM21_GHI_Signal_mV_Std: Standard deviation of the ventilated thermopile pyranometer voltage signal for global hemispherical irradiance( Kipp & Zonen CM21)
  • RAW_CM21_DHI_Signal_mV_Avg: Average voltage signal of the ventilated thermopile pyranometer for diffuse hemispherical irradiance (Kipp & Zonen CM21)
  • RAW_CM21_DHI_Signal_mV_Min: Min voltage signal of the ventilated thermopile pyranometer for diffuse hemispherical irradiance (Kipp & Zonen CM21)
  • RAW_CM21_DHI_Signal_mV_Max: Max voltage signal of the ventilated thermopile pyranometer for diffuse hemispherical irradiance(Kipp & Zonen CM21)
  • RAW_CM21_DHI_Signal_mV_Std: Standard deviation of the ventilated thermopile pyranometer voltage signal for diffuse hemispherical irradiance (Kipp & Zonen CM21)
  • RAW_CG4_LHI_Signal_mV_Avg: Average voltage signal of the ventilated thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_LHI_Signal_mV_Min: Min voltage signal of the ventilated thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_LHI_Signal_mV_Max: Max voltage signal of the ventilated thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_LHI_Signal_mV_Std: Standard deviation of the ventilated thermopile pyrgeometer voltage signal (Kipp & Zonen CG4)
  • RAW_CHP1_RS_R0_Avg: Average resistance ration RS/R0 of the temperature measurement on the body of the thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CHP1_BodyTemp_degC_Avg: Average temperature in °C of the body of the pyranometer (Kipp & Zonen CHP1)
  • RAW_CHP1_BodyTemp_degC_Min: Average temperature in °C of the body of the pyranometer(Kipp & Zonen CHP1)
  • RAW_CHP1_BodyTemp_degC_Max: Average temperature in °C of the body of the pyranometer(Kipp & Zonen CHP1)
  • RAW_CHP1_BodyTemp_degC_Std: Standard deviation in °C of the temperature of the body of the pyranometer (Kipp & Zonen CHP1)
  • RAW_CG4_RS_R0_Avg: Average resistance ration RS/R0 of the temperature measurement on the body of the thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_BodyTemp_degC_Avg: Average temperature in °C of the body of the thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_BodyTemp_degC_Min: Average temperature in °C of the body of the thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_BodyTemp_degC_Max: Average temperature in °C of the body of the thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CG4_BodyTemp_degC_Std: Standard deviation in °C of the temperature of the body of the thermopile pyrgeometer (Kipp & Zonen CG4)
  • RAW_CV50_INVALID_WIND_TOT: Number of invalid wind measurements e.g. due to rain droplets (Campbell Scientific ClimaVue50)
  • RAW_CV50_TILTNS_DEG_AVG: Tilt of instrument in ° towards in N-S direction, digital submission from the all-in one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_TILTWE_DEG_AVG: Tilt of instrument in ° towards in E-W direction, digital submission from the all-in one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_GHI_WM2_AVG: Average global (solar) hemispherical irradiance in W/m2, digital signal measured with a photodiode [low quality] pyranometer in the all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_PRECIPITATION_MM_TOT: Precipitation measured with an droplet counter in the all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_LTNGSTRIKES_CNT_TOT: Number of lightning strikes measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_LTNGDIST_KM_MAX: Maximum distance of lightning strikes measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_LTNGDIST_KM_AVG: Average distance of lightning strikes measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_WIND_MS_AVG:  Average wind speed in m/s measured by the all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_WINDDIRECTION_DEG_AVG: Wind direction in ° measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_WINDGUSTMAX_MS_AVG: Maximum wind speed in m/s measured by the all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_AIRTEMPERATURE_DEGC_AVG: Air temperature in °C measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_VAPOURPRESSURE_KPA_AVG: Vapour pressure in kPa calculated based on air temperature and relative humidity measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_PRESSUREACTUAL_KPA_AVG: Actual pressure in kPa (not reduced to sea level) measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_RELHUMIDITY_FRACTIONAL_AVG: Fractional relative humidity measured with an all-in-one weather sensor (Campbell Scientific ClimaVue50)
  • RAW_CV50_RHT_C_AVG: Internal uncorrected temperature of the all-in-one weather sensor (Campbell Scientific ClimaVue50)

Missing data are shown with -9999. Missing data and data gaps are summarized in "BRENGI-RAW_1min-202407290000_202504030000_UTC_missing_data_report.txt"

Change log:

Version 2.0 :

  • Added the combnined "RAW_1min" data table.
  • Added the text-files summarizing missing data periods.
  • The "MET_1min" data table now starts and ends at midnight of the date when measurements first started / ended.
  • Updated documentation.

Notes (English)

TECHNICAL INFO

No data quality control has been carried out. No gap-filling has been applied. 

COPYRIGHT NOTICE

Copyright Jörn Birkmann, Andreas Christen, Nektarios Chrysoulakis, and Sue Grimmond. Some rights reserved.

CREATOR NOTICE

This work is owned by the Principal Investigators (PIs) of the .

ATTRIBUTION NOTICE

The [creation and] curation of this work has been funded by the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No 855005).

DISCLAIMER NOTICE

The use of the work is at the user's own risk. The authors, the involved institutions, and/or the European Research Council accept no liability for material or non-material damage arising from the use or non-use or from the use of incorrect or incomplete information in this work. The authors, the involved institutions, and/or the European Research Council are not responsible for any use that may be made of the information in this work. The legal provisions remain unaffected.

MATERIAL NOTICE

The notices cover data in databases, text and images contained in the work.

MATERIAL URI

Urbisphere project

Files

Embargoed

The files will be made publicly available on March 31, 2027.

Additional details

Funding

European Commission
urbisphere - urbisphere - coupling dynamic cities and climate 855005

Dates

Collected
2024-07-29/2025-04-02