Published November 5, 2026 | Version v1

CSI-007: Il livello fa la differenza

  • 1. ROR icon Istituto Nazionale di Fisica Nucleare
  • 2. ROR icon Istituto Nazionale di Fisica Nucleare, Sezione di Torino

Description

An open bottle, a small outlet and a fixed collection volume provide a simple investigation of gravity-driven flow. Nursing students time how long it takes to collect 100 mL of water when the initial surface is either 5 cm or 20 cm above the same outlet. They repeat each condition five times, compare mean times and variability, and estimate flow rates. The central question is whether quadrupling the height makes collection four times faster. Students distinguish the hydrostatic pressure difference, which is proportional to height, from the ideal exit speed, which is proportional to its square root. They also examine how the falling water level affects their results and why the bottle alone cannot predict the flow rate of a clinical infusion. The resource includes a student dossier and a teacher’s guide.

Language of the teaching materials: Italian.

Files

csi-007-poster.png

Files (1.8 MB)

Name Size
md5:8ca5fee9919edc674a03bb05e50a3ef7
350.9 kB Preview Download
md5:76e6adbc76af909f4067f5144b8a4b6b
343.0 kB Preview Download
md5:31730151775556e4ece9d7c91cbef0c0
1.1 MB Preview Download

Additional details

Funding

European Commission
ERNEST - ERNEST - European Researchers Night Escape Science Team 101305138