Published October 22, 2025 | Version v1
Journal article Open

Patient-specific and interpretable deep brain stimulation optimisation using MRI and clinical review data

  • 1. Analysis and Interpretation of Biomedical Data, Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University, Prague, Czechia
  • 2. Department of Neurology, First Faculty of Medicine, Charles University, Prague, Czechia
  • 3. National Institute of Mental Health, Klecany, Czechia

Description

Background: Optimisation of Deep Brain Stimulation (DBS) settings is a key aspect in achieving clinical efficacy in movement disorders, such as the Parkinson’s disease. Modern techniques attempt to solve the problem through data-intensive statistical and machine learning approaches, adding significant overhead to the existing clinical workflows. Here, we present a geometry-based optimisation approach for DBS electrode contact and current selection, grounded in routinely collected MRI data, well-established tools (Lead-DBS) and optionally, clinical review records.

Methods: The pipeline, packaged in a cross-platform tool, uses lead reconstruction data and simulation of Volume of Tissue Activated (VTA) to estimate the contacts in optimal position relative to the target structure, and suggests optimal stimulation current. The tool then allows further interactive user optimisation of the current settings. Existing electrode contact evaluations can be optionally included in the calculation process for further fine-tuning and adverse effect avoidance.

Results: Based on a sample of 174 implanted electrode reconstructions from 87 Parkinson’s disease patients, we demonstrate that our algorithm’s DBS parameter settings are more effective in covering the target structure (Wilcoxon p < 5e-13, Hedges’ g > 0.94) and minimising electric field leakage to neighbouring regions (p < 2e-10, g > 0.46) compared to expert parameter settings. Retrospective analysis of a limited subset (n = 50) predicts comparable improved motor outcomes with expert settings (g = 0.05–0.08, p = 0.09–1), suggesting potential for similar clinical efficacy, pending prospective validation.

Conclusion: The proposed automated method for optimisation of the DBS electrode contact and current selection shows promising results and is readily applicable to existing clinical workflows. We demonstrate that the algorithmically selected contacts perform better than manual selections according to electric field calculations, without the iterative optimisation procedure.

Files

Accepted-Manuscript.PDF

Files (681.3 kB)

Name Size Download all
md5:5c000a099cfd5b9a45edc70ef58f9882
681.3 kB Preview Download

Additional details

Related works

Is supplemented by
Dataset: 10.5281/zenodo.17367094 (DOI)

Funding

Ministry of Education Youth and Sports
Brain Dynamics CZ.02.01.01/00/22_008/0004643

Dates

Accepted
2025-10-07