Published July 17, 2025 | Version v1
Journal article Open

Healing of ischemic injury in the retina

  • 1. ROR icon University of Utah

Description

Introduction

Over the past few years, we have developed techniques to maintain functional responses in the post-mortem human eye after death (Abbas, Fatima et al. “Revival of light signalling in the postmortem mouse and human retina.” Nature vol. 606,7913 (2022): 351-357. doi:10.1038/s41586-022-04709-x). However, to maintain longer periods of retinal function, biopsy sampling had to be done in total darkness and as quickly as possible. This, compounded by the need for precision sampling within 3 mm, presented a major challenge. In response to this, we developed a program to interface with the Heidelberg Spectralis OCT hardware and HEYEX software to automatically locate the desired sampling area and send signals to attached stepper motors to quickly align the biopsy punch. This project invovled several custom made parts using Fusion 360 and an object detection model built on Ultralytics YOLO v8 architecture.

Organization

Within this repository, you'll find the mechanical drawings and components used to adapt the traditionally upright clinical Heidelberg Spectralis to a more accesible transverse orientation, suitable for analyzing ex vivo specimens.

All relevent Python code used to train and test the object detection model and to sample the specimen are included, along with the training data.

Files

Code.zip

Files (927.9 MB)

Name Size Download all
md5:439276286259413bd299cf51dfb817b8
233.1 MB Preview Download
md5:31939535ab6bcdd0fcaab2710de17b9e
35.8 MB Preview Download
md5:e53f2bfec91eaa86f9cba4595b6a8a42
659.0 MB Preview Download