Published February 19, 2025 | Version v1
Dataset Open

Data sets of interlaboratory comparison of alternating and rotational loss measurements in non-oriented Fe-Si Sheets

  • 1. ROR icon Istituto Nazionale di Ricerca Metrologica
  • 2. ROR icon Université Claude Bernard Lyon 1
  • 3. ROR icon Polytechnic University of Turin
  • 4. ROR icon Université Paris-Saclay

Abstract

We report on a comparison performed by four European laboratories [INRIM (Torino), Ampère Lab (Lyon), Politecnico di Torino, and SATIE Lab (Paris Saclay)] regarding the measurement of the magnetic energy losses in non-oriented Fe–Si sheets (physical parameters reported in Table I) under alternating and rotational fields. The laboratories used different Rotational Single Sheet Testers (RSSTs) with independently developed hardware and software tools and methods. Both open and closed magnetic circuits were employed, using circular, cross-shaped, and single-strip samples.

Files