A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTION SYSTEM USING DIRECT POWER CONTROL METHOD
Creators
Description
Power quality problems in power systems have been i mproved due to nonlinear loads. To compensate these problems Direct Power Compensator was proposed in this paper. A Direct Power Compensator (DPC) is proposed in this paper to elim inate the harmonic currents,compensate power factor and voltage unbalance problems created by th e nonlinear loads present in three phase systems. A DPC contains back to back converter by sharing th e same dc link power and v/v transformer to provide a voltage balance in transmission line. Hys teresis harmonic current regulator is used to produce pulse for back to back converter. A control ler maintains the dc-link voltage and compensates the power factor,harmonic currents. A comparative analysis for traction system with and without DPC was performed using MATLAB Simulink . Simulation results show the controller advantages and the applicability of the proposed me thod in railway systems.