sEMG-based Gesture Recognition with Spiking Neural Networks on Low-power FPGA
Description
Classification of surface electromyographic (sEMG) signals for the precise identification of hand gestures is a crucial area in the advancement of complex prosthetic devices and human-machine interfaces. This study presents a real-time sEMG classification system, exploiting a Spiking Neural Network (SNN) to distinguish among twelve distinct hand gestures. The system is implemented on a Lattice iCE40-UltraPlus FPGA, explicitly designed for low-power applications. Evaluation on the NinaPro DB5 dataset confirms an accuracy of 85.6%, demonstrating the model’s effectiveness. The power consumption for this architecture is approximately 1.7 mW, leveraging the inherent energy efficiency of SNNs for low-power classification.
This preprint has not undergone peer review or any post-submission improvements or corrections. The Version of Record of this contribution is published in Design and Architectures for Signal and Image Processing (DASIP 2024) , and is available online at 10.1007/978-3-031-62874-0_2 .
Files
DASIP24_14.pdf
Files
(1.2 MB)
Name | Size | Download all |
---|---|---|
md5:adfb1b53123b16e562f0ef72d34be08a
|
1.2 MB | Preview Download |
Additional details
Funding
Dates
- Accepted
-
2023-12-16