Published August 21, 2024 | Version v1
Publication Open

Impact of Fixation of Camel Lymph Node Cells on Marker Expression Stability in Flow Cytometry

Authors/Creators

Description

ABSTRACT: Single cell immunophenotyping by flow cytometry has proven a useful and high sensitive method for the analysis of immune cell composition and phenotype in different lymphatic and non-lymphatic tissues. Fixation of stained cells is usually recommended when the cells need to be preserved for later analysis by flow cytometry to avoid changes in cell morphology and expression of the level of cellular antigens. In the present study, a stain-fix approach was used in combination with flow cytometry to investigate the impact of fixation of camel lymph node cell suspension (n = 5 camels) after labeling with monoclonal antibodies to some leukocyte antigens on their cellular composition and expression density of immune cell markers. The obtained results indicated that camel lymph node cell suspension stained with fluorochrome-conjugated mAbs to leukocyte antigens and fixed with paraformaldehyde (PFA) will keep stable values for their immune cell composition for at least six days when analyzed by flow cytometry. However, if cell subsets were to be identified, fixation may result in different values that were obtained when analyzing fresh stained unfixed cells. Especially the instability in the fluorescence intensity of CD14, CD172a, and MHCII will lead to significant changes in the frequency of monocyte subsets (classical versus intermediate or non-classical) and the identification of macrophage functional subtype (M1 versus M2). Similarly, the instability in CD44 expression may affect the identified phenotype of T cells with significantly lower frequency of activated T cells. In conclusion, flow cytometric data collected from stained and PFA-fixed cell suspension prepared from camel lymph nodes should be interpreted with care if the functional subtype of cells is to be identified based on surface molecule expression.

 

https://wvj.science-line.com/attachments/article/81/WVJ14(2)%20158-168,%202024.pdf

Files

WVJ14(2) 158-168, 2024.pdf

Files (417.9 kB)

Name Size Download all
md5:b5a691bd42ca745c75fcecb9c02974d2
417.9 kB Preview Download

Additional details

Dates

Accepted
2024-06-25

References

  • Aalbers AM, van den Heuvel-Eibrink MM, Baumann I, Dworzak M, Hasle H, Locatelli F, De Moerloose B, Schmugge M, Mejstrikova E, Novakova M et al. (2015). Bone marrow immunophenotyping by flow cytometry in refractory cytopenia of childhood. Haematologica, 100(3): 315-323, DOI: https://www.doi.org/10.3324/haematol.2014.107706
  • Almohammed H, Alhafiz GA, Alghatam FH, and Hussen J (2022). The impact of camel leukocytes fixation on cell count and monoclonal antibodies reactivity in flow cytometry. World's Veterinary Journal, 12(1): 74-80. DOI: https://www.doi.org/10.54203/scil.2022.wvj10
  • Barut GT, Kreuzer M, Bruggmann R, Summerfield A, and Talker SC (2022). Single-cell transcriptomics reveals striking heterogeneity and functional organization of dendritic and monocytic cells in the bovine mesenteric lymph node. Frontiers in Immunology, 13: 1099357. DOI: https://www.doi.org/10.3389/fimmu.2022.1099357