Fracture Dielectric Elastomers
Authors/Creators
- 1. Institute of Applied Mechanics, Friedrich-Alexander-Universität Erlangen–Nürnberg, Egerlandstr. 5, 91058, Erlangen, Germany
Description
This dataset contains the experimental raw data from the mechanical and electro-mechanical testing of soft dielectric elastomers: unfilled PDMS and BaTiO3-filled PDMS. The data have not been filtered.
Every specimen is tested under tensile loading until full rupture.
All specimens had a thickness of 3mm. The initial length between grips was set to 40mm.
The files are named according to:
- the type of sample (Unfilled_PDMS/BaTiO3_Filled),
- the width of the sample (w30mm/w50mm),
- the length of the pre-cut (c0mm/c3mm/c5mm/c6mm/c9mm/c10mm/c12mm/c15mm/c20mm/c25mm),
- the voltage applied in the thickness direction during tensile deformation (0kV/4kV/8kV),
- and the number of the experiment up to the total number of repetitions under the same test conditions (R1/R2/R3 for filled samples and R1/R2 for unfilled samples).
If this dataset is used for research or industrial purposes, please cite:
M.A. Moreno-Mateos, M. Mehnert, P. Steinmann. "Electro-mechanical actuation modulates fracture performance of soft dielectric elastomers", International Journal of Engineering Science, vol.195, 104008. (2024). https://doi.org/10.1016/j.ijengsci.2023.104008
Further explanation regarding the specimen preparation and experimental setup can be found in the aforementioned work.
Files
Data.zip
Files
(17.3 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:f7fa1f59854fd8f15ef9716a2403b796
|
17.3 MB | Preview Download |
|
md5:e15158738495f8c60d5a04485e561a61
|
1.3 kB | Preview Download |
Additional details
Related works
- Is referenced by
- Journal article: 10.1016/j.ijengsci.2023.104008 (DOI)