Uncovering wall-shear stress dynamics from neural-network enhanced fluid flow measurements
Authors/Creators
Description
This dataset is part of the following publication:
E. Lagemann, S. L. Brunton, C. Lagemann, "Uncovering wall-shear stress dynamics from neural-network enhanced fluid flow measurements", 2024, Proceedings of the Royal Society A (arXiv: http://arxiv.org/abs/2310.11147)
The dataset contains experimental particle-image velocimetry (PIV) data and corresponding calibration images of three test cases: turbulent channel flow (TCF), wavy turbulent channel flow (TWCF), elastic blood vessel flow (VESSEL).
TCF data:
The TCF data consist of 5 measurement runs (M1-M5) with identical conditions at a friction Reynolds number of 1000. The measurement plane is oriented in streamwise/wall-normal direction at the channel centerline. Seeding: DEHS with a mean diameter of 3 um. Camera: Photron SA3 with Tamron 180 mm lens. Laser: Quantronix Darwin Duo 40. Frame rate: 2000 Hz. Puls distance: 0.000163 s. Temperature: 283.15 K. Calibration: dot distance of 5 mm.
TWCF data:
The wavy wall contour is a sine wave with an amplitude of 5 mm (0.1 channel half height) and a wavelength of 100 mm (2 channel half heights). Friction Reynolds number of 200. The measurement plane is oriented in streamwise/wall-normal direction at the channel centerline. Seeding: DEHS with a mean diameter of 3 um. Camera: PCO edge 5.5 with Zeiss 100 mm macro lens. Laser: New Wave Solo 200XT. Frame rate: 15 Hz. Puls distance: 0.000350 s. Temperature: 298.15 K. Calibration: dot distance of 5 mm.
VESSEL data:
An oscillatory flow is generated in the closed circuit by a controlled piston pump. The fluid flow is a water-glycerin mixture, which approximates the blood flow properties and matches the refractive index of the vessel model. Reynolds number: 390, Womersley number: 5.27. Vessel material: RTV615. Measurement plane: streamwise-radial. Seeding: Hollow glass spheres with a mean diameter of 10 um. Camera: Fastcam PCI 1024 with Tamron 180 mm lens. Laser: Quantronix Darwin Duo 40. Frame rate: 200 Hz. Puls distance: 0.006 s. Temperature: 298.75 K. Density: 1143.3. Dynamic viscosity: 0.006422 Calibration: millimeter paper.
Files
TCF_calibration_image.tif
Files
(30.9 GB)
| Name | Size | Download all |
|---|---|---|
|
md5:3b615708bc63518dd66596eeb28e564d
|
1.6 MB | Preview Download |
|
md5:23ffc69891cdd65a7957f10c60d5eac7
|
2.4 GB | Preview Download |
|
md5:8b7a5ed5807dbbc2dff32689dc2c65ef
|
2.5 GB | Preview Download |
|
md5:955b53fa02c1e3f1ae2f82d8228124a4
|
2.5 GB | Preview Download |
|
md5:cc0756cfc3882739fb5c88dd8d4b836d
|
2.5 GB | Preview Download |
|
md5:ee54e40bc857d5c59b9eda44fd779fa8
|
2.5 GB | Preview Download |
|
md5:6b353d71381a078d129d02574560bdae
|
13.4 GB | Preview Download |
|
md5:a259c54fffa2522cc1e23dcb19b82e8d
|
10.5 MB | Preview Download |
|
md5:f38dea2faf40c40483f4fa436355e14e
|
5.2 GB | Preview Download |
|
md5:a448d5f14d71c6abb13532cae13524bd
|
1.0 MB | Download |
Additional details
Software
- Repository URL
- https://github.com/cl126162/WSSflow
- Programming language
- Python