Published June 1, 2023 | Version v1
Project milestone Open

HTS Nuclotron Cable Produced

Description

Two samples of the Nuclotron CORT cable were manufactured and tested for their magnetization loss. The cables were designed to have a critical current of 1350 A at 77.3 K and around 10 kA at 4.2 K. The cable was made using commercial REBCO coated conductor from a non-European manufacturer, which had excellent mechanical properties. The experiments were conducted at IEE Bratislava and at University of Twente in Enschede at 77.3 K and 4.2 K, respectively. The results confirm the expectation that there are negligible electrical contacts between the copper-stabilized tape strands and that it is possible to estimate hysteresis loss analytically for accelerator-magnet-relevant operating conditions.

Files

IFAST_MS36_Final.pdf

Files (607.8 kB)

Name Size Download all
md5:6e45397c73620595636d564dfbddc1ff
607.8 kB Preview Download

Additional details

Funding

I.FAST – Innovation Fostering in Accelerator Science and Technology 101004730
European Commission

References

  • I.FAST MS36