Published June 1, 2023 | Version v1
Project milestone Open

HTS Nuclotron Cable Produced

Authors/Creators

Description

Two samples of the Nuclotron CORT cable were manufactured and tested for their magnetization loss. The cables were designed to have a critical current of 1350 A at 77.3 K and around 10 kA at 4.2 K. The cable was made using commercial REBCO coated conductor from a non-European manufacturer, which had excellent mechanical properties. The experiments were conducted at IEE Bratislava and at University of Twente in Enschede at 77.3 K and 4.2 K, respectively. The results confirm the expectation that there are negligible electrical contacts between the copper-stabilized tape strands and that it is possible to estimate hysteresis loss analytically for accelerator-magnet-relevant operating conditions.

Files

IFAST_MS36_Final.pdf

Files (607.8 kB)

Name Size Download all
md5:6e45397c73620595636d564dfbddc1ff
607.8 kB Preview Download

Additional details

Funding

European Commission
I.FAST - Innovation Fostering in Accelerator Science and Technology 101004730

References

  • I.FAST MS36