Published January 30, 2023 | Version CC BY-NC-ND 4.0
Journal article Open

Translational Calibration for Contact Type Three-Dimensional Position-Measuring Instruments

  • 1. Department of Information Science and Technology, National Institute of Technology (KOSEN), Yuge College, Ehime Prefecture, Japan.

Description

Abstract: In Japan, as the number of sewerage management facilities increases, continuous maintenance of drainage pipes and sewage pipes is considered important. However, it is grinding for operators to perform the expansive in-pipe inspection. Therefore, in recent years, inspections using stand-alone type piping inspection robots have been actively used. Inside of the pipe, there are disturbances such as unevenness, sludge, or dents at pipe joints which cause slips and tumbles of the robot. Therefore, the conventional ways of approaching those disturbances have been adjusting the size of the robot and tires according to the diameter of the pipe to prevent tipping over. We are exploring tip-over prevention measures by the software approach through advanced straight-ahead control. Currently, we are in the stage of verifying the self-position estimation necessary to realize straight-ahead control, and equipment for that purpose is required. However, to measure the position and posture of the robot inside the curved pipe, a special three-dimensional position-measuring device is required. Therefore, we have developed a three-dimensional position-measuring instrument for pipe inspection robots, but there is still an error in the absolute positioning accuracy. In this paper, to solve this error problem and make it precise, we propose a method to apply the calibration method used in the manipulator to the measuring instrument. Also, the kinematic model and its calibration parameters are explained, and a method of deleting unnecessary redundant parameters and parameter estimation by Newton's method is presented. Furthermore, in a comparative verification using a measuring instrument proposed in the paper, the positional accuracy after calibration is within a range of approximately ±1.0 mm, and the variation is also within a range of ±0.5 mm, which shows that the proposed method is effective.

Notes

Published By: Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP) © Copyright: All rights reserved.

Files

E73840111523.pdf

Files (786.7 kB)

Name Size Download all
md5:d3c56bddef2c6f8d03e6b8dfae258c14
786.7 kB Preview Download

Additional details

Related works

Is cited by
Journal article: 2277-3878 (ISSN)

References

  • Japan institute of wastewater engineering technology, "Development foundation survey of sewerage facilities management robot", Sewer new technology Annual report of the Institute, 1992, pp.43-52.
  • Rome, E., Hertzberg, J., Kirchner, F., Licht, U. and Christaller, T., "Towards Autonomous Sewer Robots: the MAKRO Project", Urban Water, Vol. 1, 1999, pp. 57-70
  • Streich, H. and Adria, O., "Software approach for the autonomous inspection robot MAKRO", in Proceedings of the 2004 IEEE International Conference Robotics and Automation, 2004, pp. 3411- 3416.
  • Birkenhofer, C., Regenstein, K., Zöllner, J. M. and Dillmann, R., "Architecture of multi-segmented inspection Robot KAIRO-II", DOI: 10.1007/978-1-84628-974-3_35, In book: Robot Motion and Control, 2007, pp.381-389.
  • Ayaka, N., Kazutomo, F., Toshikazu, S., Mikio, G. and Hirofumi M., "Prototype design for a piping inspection robot", 43rd Graduation Research Presentation Lecture of Student Members of the JSME, 2013, 716.
  • Kazutomo, F., Yoshiki, I. and Hirofumi M., "Modularization for a piping inspection robot", 2013 Symposium on System Integration, 2013, pp.1297-1300.
  • Kazutomo, F., Toshikazu, S., Mikio, G., Yoshiki, I. and Hirofumi M., "Miniaturization of the piping inspection robot by modularization", 44th Graduation Research Presentation Lecture of Student Members of the JSME, 2014, 613.
  • Hirofumi, M., Takuya, K., Kazutomo, F., Yoshiki, I., Toshikazu, S. and Mikio, G., "Research and development about a piping inspection robot - Report1: Prototype design for a miniaturization -", Bulletin of National Institute of Technology, Yuge College, Vol. 36, 2014, pp.79- 82.
  • Hirofumi, M., Yoshiki, I., Toshikazu, S. and Mikio, G., "Research and development about a piping inspection robot - Report2: Prototype design for maintenance improvement -", Bulletin of National Institute of Technology, Yuge College, Vol. 37, 2015, pp.75-79.
  • Hirofumi M., Ryota, K., "Development of a small autonomous pipe inspection robot (Modularization of hardware using the technique of wooden mosaic work)", Transactions of the Japan Society of Mechanical Engineers, Vol.82, No.839, 2016, pp.1-16.
  • Hirofumi M., "Automatic Compensation of the Positional Error Utilizing Localization Method in Pipe", International Journal of Recent Technology and Engineering (IJRTE), Vol.9, No.6, 2021, pp.151-157.
  • Yuki, Y., Yoshiki, I., Hirofumi, M., "Self-localization Measurement of the Piping Inspection Robot by a ARtoolkit", Transactions of the Japan Society of Mechanical Engineers, No. 165-1, 2016, 502.
  • Ayano, T., Hirofumi, M., "Accuracy Improvement of the Measuring Instrument for the Piping Inspection Robot", The Japan Society of Mechanical Engineers Chugoku-Shikoku Branch, the 47th Conference on the Graduation Thesis for Undergraduate Students,2017, 921.
  • Ayano, T., Hirofumi, M., "Tilt Adjustment to Measuring Instrument for Piping Inspection Robot", Transactions of the Japan Society of Mechanical Engineers, No. 185-1, 2018, 1304.
  • Keita I., Hirofumi M., "Hardware Design for the Contact Type Measuring Instrument", The Japan Society of Mechanical Engineers Chugoku-Shikoku Branch, the 52nd Conference on the Graduation Thesis for Undergraduate Students, 2022, 11b4.
  • . Ibuki T., Hirofumi M., "Data Reception of the Contact Type Measuring Instrument using BLE", Transactions of the Japan Society of Mechanical Engineers, No. 225-1, 2022, 09a1.
  • Kohei S., Hirofumi M., "Posture Measurement of a Robot using the Contact Type Measuring Instrument", Transactions of the Japan Society of Mechanical Engineers, No. 225-1, 2022, 09a2.
  • Hirofumi M., "A Contact Type Three Dimensional Position Measuring Instrument for Verification of a Piping Inspection Robot", International Journal of Recent Technology and Engineering (IJRTE), Vol.10, No.6, 2022, pp.65-72.
  • Masaru I., Shigeyuki S., Masayoshi K., Yoshio M., "Robot Manipulator Calibration for 3D Model Based Robot Systems", Journal of the Robotics Society of Japan, Vol.7, No.2, 1989, pp.74-83

Subjects

ISSN: 2277-3878 (Online)
https://portal.issn.org/resource/ISSN/2277-3878
Retrieval Number: 100.1/ijrte.E73840111523
https://www.ijrte.org/portfolio-item/E73840111523/
Journal Website
https://www.ijrte.org/
Publisher: Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP)
https://www.blueeyesintelligence.org/