Published May 18, 2023 | Version v1
Journal article Open

Efficient replacement of the radioactive sources in the gas-filled surge arresters construction for the insulation co-ordination at the low voltage level

  • 1. Faculty of Technology and Metallurgy, University of Belgrade, Belgrade, Serbia
  • 2. Faculty of Electrical Engineering, University of Belgrade, Belgrade, Serbia
  • 3. Electrical Engineering Institute "Nikola Tesla", University of Belgrade, Belgrade, Serbia

Description

Abstract

The possibility of the classical response rate engineering and the long-term deconditioning of the gas-filled surge arresters is considered in this paper. The obtained results are compared with the same results obtained with the gas-filled surge arrester with application of an alpha radioactive source. The work is of an experimental nature. Experiments were performed on the multipurpose gas-filled surge arrester model under well-controlled conditions. The measurement uncertainty of the experimental procedure was less than 8 %. The results were processed by statistical data processing software. To draw impulse characteristics, the law of constancy of surfaces below the impulse voltage in the volt-second area, was used.

Files

1451-39942002130N.pdf

Files (729.6 kB)

Name Size Download all
md5:041ba0566b76bc9ed4c337217efe978e
729.6 kB Preview Download