Published March 22, 2023 | Version v1
Dataset Open

A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging

  • 1. Department of Mechanical Engineering, University College London, London, UK
  • 2. Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
  • 3. European Synchrotron Radiation Facility, Grenoble, France

Description

Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast cineradiography with operando gas chromatography, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (2 to 3 times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gases remain unchanged. Coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical, yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications.

Files

Analysis.zip

Files (93.4 GB)

Name Size Download all
md5:563c65af0738117fa2b5daffb1946346
54.4 MB Preview Download
md5:16429fc4a62b077c67133ce31d4a8ea1
649.7 MB Preview Download
md5:5b4cd5bcba625be47d0f2be1f4f7ac46
92.7 GB Preview Download

Additional details

Related works

Is supplement to
Preprint: 10.1101/2023.02.14.528474 (DOI)