Published June 30, 2022
| Version v1
Conference paper
Open
Improvement of Spill Quality for Slowly Extracted IONS at GSI-SIS18 via Transverse Emittance Exchange
- 1. GSI, Darmstadt, and Goethe Univ, Frankfurt, Germany
- 2. GSI, Darmstadt, Germany
Description
The temporal beam stabilization of slowly extracted beams from the synchrotron within several seconds is crucial for fulfilling the demands of fix-target experiments. Results from previous investigations suggest that the transit time spread can be increased by reducing the beam emittance in the plane of extraction. Increased transit time spread is known to cut-off high frequency noise introduced by magnet power supplies. A pilot experiment was performed at SIS18 at GSI to introduce transverse emittance exchange, resulting in the circulating beam’s smaller horizontal beam size. The improvement of the spill micro structure is reported in this contribution.
Files
P1_SpillQuality_PeterForck.pdf
Files
(544.7 kB)
Name | Size | Download all |
---|---|---|
md5:b501e2bca3252d9fb7a9adc0716178fa
|
544.7 kB | Preview Download |