Driven steel beams with grout injection (MV-piles) are since the 80’s in use in the Rotterdam harbour to deliver tension
bearing capacity for anchoring large deep-sea quay walls.
This paper discusses the results from pile load tests on two sites within a historical context of port development and
evolving load tests. The tested tension piles were fully instrumented with fiber optic strain sensors allowing for
capturing a continuous strain profile along the full length of the piles. Practical information on instrumentation, testing
and interpretation will be illustrated with actual test results.