Output voltage control of a PMSG with the DPC-SVM technique and high-order sliding mode
- 1. Laboratoire Génie Electrique et Energies Renouvelables (LGEER), Electrical Engineering Department, Hassiba Benbouali University, Chlef, Algeria
Description
This paper aims to study the control of the output voltage of a wind turbine (WT) which is composed of a permanent magnet synchronous generator (PMSG) connected to an inverter/rectifier. The first tested control on PMSG is based on the classical direct power control (CDPC); this technique uses the active and reactive power as a control variable. Then, to improve the quality of energy and evaluate the performance of the system, we proposed a highorder sliding mode (HOSM) with space vector modulation (SVM) to control the output voltage. As a result, the proposed approach presents attractive features such as the chattering-free behavior of the sliding mode. This system was designed for a wind power conversion application in the case of an isolated site. The computer simulations were provided to verify the validity of the proposed control algorithm using the MATLAB/Simulink software.
Files
18 23664.pdf
Files
(1.0 MB)
Name | Size | Download all |
---|---|---|
md5:b5ed8abad81733eea0c663848e26462c
|
1.0 MB | Preview Download |