Published November 30, 2020 | Version v1
Journal article Open

Simulation of 28 Element Ultrasound Transducer for Non-Destructive Evaluation (NDE) Applications

Creators

  • 1. Department Electronics and Communication, Amity University, Maharashtra Mumbai, Maharashtra, India
  • 1. Publisher

Description

Quantitative ultrasound based Non-Destructive Evaluation (NDE) is one of the leading test procedures used in testing of finished products in manufacturing industry. It can detect surface as well as subsurface flaws accurately. It is also employed in medical diagnostic for various purposes. The main objective of this paper is to simulate 28 element ultrasound transducer pair for through transmission testing procedure. The simulation is done using k-Wave toolbox (open source toolbox) and MATLAB. The simulation results show that the received signal strength and resolution is far more improved over single and dual element transducer probes available in the market. The simulation of wave propagation through three layered aluminum material is also shown in the results. Based on results, it can be concluded that 28 element transducer pair are the optimum solution for NDE evaluation challenges with reference to cost, size, and design complexity.

Files

D5012119420.pdf

Files (195.0 kB)

Name Size Download all
md5:dcd44fbd3883a094cba96c345bdfeefb
195.0 kB Preview Download

Additional details

Related works

Is cited by
Journal article: 2277-3878 (ISSN)

Subjects

ISSN
2277-3878
Retrieval Number
100.1/ijrte.B2107078219