Measurement of energies and intensities of multiple ionization satellite (MIS) excited in light elements by helium ion beams

Description

TNA project number: 19001708-ST

Measurement of energies and intensities of multiple ionization satellite (MIS) excited in light elements by helium ion beams

Scientific background:

Over 1600 X-ray spectra have been collected from the alpha particle X-ray spectrometers on Mars rovers including the present Curiosity rover. The spectra are excited by the radionuclide 244Cm, which emits 5 MeV He ions for PIXE and Pu L X-rays for XRF. These spectra provide elemental analysis of rocks, soils and dust as part of the quest to identify formerly habitable (water-bearing) environments. Applicant is a member of the Curiosity APXS team within NASA’s Mars Science Laboratory. Excitation of K X-rays by 5 MeV He ions produces also energy-shifted satellites due to 1, 2 or 3 L-shell spectator vacancies. These cause significant distortion of the diagram lines and worsen the quality of spectrum fits by the GUPIX(Mars) code. An MIS database is needed to support a correction procedure that is already devised. This work will increase analytical accuracy and will also support more accurate terrestrial PIXE analysis using alpha beams, especially when partnered with RBS; this could lead to increased use of these two IBA methods in a complementary manner.

 

Measurements performed within TNA project:

The wavelength-dispersive in-vacuum x-ray spectrometer of J. Stefan Institute (Ljubljana, Slovenia) [1] have been used to record high energy resolution KaLN X-ray spectra of Ca and Cr induced in collisions with MeV alpha particles. The targets used were metallic Cr, Cr2O3, and CaF2. The KaLN X-ray spectra of Cr and Cr2O3 were measured using three different energies of He ions, namely 3 MeV, 4 MeV and 5 MeV. For CaF2 we have collected only spectra induced with 5 MeV He beam. The main purpose of the experiment was to record KaLN spectra with good enough statistics to determine precisely energy/intensity of the corresponding satellite lines. The results for the energy shifts and relative intensities of the groups will be incorporated in the MIS database providing an empirical means for inclusion of one peak per satellite group when modelling energy-dispersive spectra (GUPIX(Mars) code).

[1] M. Kavčič, M. Budnar, A. Mühleisen, F. Gasser, M. Žitnik, K. Bučar, R. Bohinc, Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range, Rev. Sci. Instr. 83, 033113 (2012). http://dx.doi.org/10.1063/1.3697862

 

Data files:

We are sharing the detector files (a series of single exposure 2D raw images) collected by the Andor DX438-BV CCD camera (770 × 1152 pixels with pixel size 22.5×22.5 μm2) after the diffraction on the crystal analyzer. The horizontal axis of the detector corresponds to the dispersion axis and diffracted photons are detected at different horizontal positions according to their wavelength, the vertical axis of the detector serves mainly to accumulate more statistics. The final emission spectra are obtained from the corresponding detector files using the home-written data processing software.

 

 

Notes

TNA project number: 19001708-ST

Files

Files (6.2 GB)

Name Size
md5:9d47cb25013c970692ce94b5dbab0617
231.5 MB Download
md5:e955a95c1707ca99fd8eee6fcaa26b0f
231.2 MB Download
md5:cb42d11715183491d3c6ec7586bb3b96
1.7 GB Download
md5:e2ec45243c8762c597c7b6982afbaa3c
1.3 GB Download
md5:4825e007420451ebc7cb9fd4daf2b196
463.4 MB Download
md5:9d014dcc4ce3a4a5e622f81e15c2f55e
515.3 MB Download
md5:912817f6f9553ec5c31a6787538f48c2
749.4 MB Download
md5:b52189dd85a27175198b4c258f1b5b6c
580.0 MB Download
md5:5097d151f1b8820eb8cc87fc26976594
174.4 MB Download
md5:8b2f57ca2aa3b106fb1c63bfed830eb6
172.9 MB Download

Additional details

Related works

Cites
Journal article: 10.1063/1.3697862 (DOI)

Funding

European Commission
RADIATE - Research And Development with Ion Beams – Advancing Technology in Europe 824096

References

  • M. Kavčič, M. Budnar, A. Mühleisen, F. Gasser, M. Žitnik, K. Bučar, R. Bohinc, Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range, Rev. Sci. Instr. 83, 033113 (2012). http://dx.doi.org/10.1063/1.3697862