Supplementary material: Modeling and Compensating Temperature-dependent Non-uniformity Noise in IR Microbolometer Cameras
Creators
- 1. Electrical Engineering Department and Center for Optics and Photonics, Universidad de Concepción, Concepción, Chile
Description
Abstract: Images rendered by uncooled microbolometer-based infrared (IR) cameras are severely degraded by the spatial non-uniformity (NU) noise. The NU noise imposes a fixed-pattern over the true images, and the intensity of the pattern changes with time due to the temperature instability of such cameras. In this paper, we present a novel model and a compensation algorithm for the spatial NU noise and its temperature-dependent variations. The model separates the NU noise into two components: a constant term, which corresponds to a set of NU parameters determining the spatial structure of the noise, and a dynamic term, which scales linearly with the fluctuations of the temperature surrounding the array of microbolometers. We use a black-body radiator and samples of the temperature surrounding the IR array to offline characterize both the constant and the temperature-dependent NU noise parameters. Next, the temperature-dependent variations are estimated online using both a spatially uniform Hammerstein-Wiener estimator and a pixelwise least mean squares (LMS) estimator. We compensate for the NU noise in IR images from two long-wave IR cameras. Results show an excellent non-uniformity correction performance and a root mean square error of less than 0.25◦C, when array’s temperature varies approximately 15◦C.
Files
Supplementary_Material.zip
Files
(371.7 MB)
Name | Size | Download all |
---|---|---|
md5:dd5c3f3af457bdf30b28882c0304c612
|
371.7 MB | Preview Download |