Single-flicker online SSVEP BCI datset
- 1. Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
- 2. Department of Psychology, School of Social Sciences, Tsinghua University, Beijing, China
- 3. Department. of Neurophysiology and Pathophysiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
Description
The zip archive contains EEG data from a newly developed brain-computer interface paradigm. The method is described in [1], and the dataset has been recorded for the application described in [2]. The two folders in the archive contain data from the training (offline) session and from the online session.
Training data: Each subject has two training sessions. The .xdf files were generated by the Lab Streaming Layer (https://github.com/sccn/labstreaminglayer) from EEG data that were recorded using a BioSemi 32 channel amplifier. The files name after (subject_number)_(session_num).xdf. Each file includes 200 trials (50 trials for each direction).
Online data: Each file contains data from one round of the game. The file name pattern is (subject_num)_(repeat_num) _(ramdon_background_num).mat. The Matlab data structure contains the following fields:
data. fsample: sampling rate (512 Hz)
data.trial:  EEG signals for each step
data.time: time series of EEG signals for each step
data.class: classifier output for each step
[1] Maye A, Zhang D, Engel AK (2017) "Utilizing Retinotopic Mapping for a Multi-Target SSVEP BCI With a Single Flicker Frequency", IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 25, no. 7, pp. 1026-1036, July 2017, doi: 10.1109/TNSRE.2017.2666479.
[2] Chen J, Zhang D, Engel AK, Gong Q, Maye A (2017) "Application of a single-flicker online SSVEP BCI" for spatial navigation", PLoS ONE, 12(5): e0178385. https://doi.org/10.1371/journal.pone.0178385
Notes
Files
      
        single flicker SSVEP BCI raw data.zip
        
      
    
    
      
        Files
         (5.8 GB)
        
      
    
    | Name | Size | Download all | 
|---|---|---|
| md5:30db5e4ca9a68b25d4cf008feab63698 | 5.8 GB | Preview Download | 
Additional details
References
- Maye A, Zhang D, Engel AK (2017) "Utilizing Retinotopic Mapping for a Multi-Target SSVEP BCI With a Single Flicker Frequency", IEEE Transactions on Neural Systems and Rehabilitation Engineering, in press.
- Chen J, Zhang D, Engel AK, Gong Q, Maye A (2017) "Application of a single-flicker online SSVEP BCI for spatial navigation", PLoS ONE, in press.
