Published May 1, 2014 | Version v1
Journal article Open

A radar-based monitoring of the Collserola tower (Barcelona)

  • 1. Centre Tecnològic de Telecomunicacions de Catalunya

Description

This paper reports a set of experiments aiming at evaluating the capability of an innovative radar technique to measure the dynamic response of a 268 m high tower, the Collserola tower located in Barcelona, and its guys; the tension force of some guys is also estimated from the obtained vibration frequencies. The applied procedure was based on the use of a coherent radar system: temporal samples acquired using different observation geometries were processed to retrieve the vibration characteristics of both the tower and its guys. This was attained by observing the tower in a fully remote sensing mode, i.e. several hundred metres from the object, without installing any reflector on the tower, and under micro-tremor and wind-induced excitation. During the campaigns, which were spread over three years, the investigated technique demonstrated its capability to measure the dynamic response for a number of different points of the tower with high repeatability. The performed experiments also allowed distinguishing and characterizing the different contributions of the tower and the guys.

Files

A_radar-based_monitoring_of_the_Collserola_tower_Barcelona.pdf

Files (5.9 MB)