Info: Zenodo’s user support line is staffed on regular business days between Dec 23 and Jan 5. Response times may be slightly longer than normal.

Published November 13, 2020 | Version v1
Journal article Open

Biomass Steam Gasification, High-Temperature Gas Cleaning, and SOFC Model: A Parametric Analysis

  • 1. Department of Agricultural and Forestry Sciences (DAFNE), Tuscia University of Viterbo, Via San Camillo de Lellis, snc, 01100 Viterbo, Italy
  • 2. Department of Industrial and Information Engineering and Economics, University of L'Aquila, Via San Giovanni Gronchi 18, 67100 L'Aquila, Italy
  • 3. CREAT, Centro di Ricerca su Energia, Ambiente e Territorio, Università Telematica eCampus, 22060 Novedrate, Italy
  • 4. Department of Nuclear, Subnuclear and Radiation Physics, Marconi University, 00193 Rome, Italy

Description

Gasification technology is actually one of the most effective ways to produce power and hydrogen from biomass. Solid oxide fuel cells (SOFCs) have proved to be an excellent energy conversion device. They can transform the chemical energy content in the syngas, produced by a gasifier, directly into electrical energy. A steady-state model of a biomass-SOFC was developed using process simulation software, ASPEN Plus (10, AspenTech, Bedford, MA, USA). The objective of this work was to implement a biomass-SOFC system capable of predicting performance under diverse operating conditions. The system is made of a gasification zone, gas cleaning steps, and SOFC. The SOFC modelling was done without external subroutines, unlike most models in the literature, using only the existing ASPEN Plus blocks, making the model simpler and more reliable. The analysis of the syngas composition out of each cleaning step is in accordance with literature data. Then, a sensitivity analysis was carried out on the main parameters. The results indicate that there must be a trade-off between voltage, electrical efficiency, and power with respect to current density and it is preferable to stay at a low steam-to-biomass ratio. The electrical efficiency achieved under the operating conditions is 57%, a high value, making these systems very attractive. 

Files

energies-13-05936.pdf

Files (2.4 MB)

Name Size Download all
md5:13baddcafc5a54b0f75a9819a223189e
2.4 MB Preview Download

Additional details

Related works

Is referenced by
Journal article: 10.3390/en13225936 (DOI)

Funding

BLAZE – Biomass Low cost Advanced Zero Emission small-to-medium scale integrated gasifier-fuel cell combined heat and power plant 815284
European Commission