Published October 10, 2021 | Version 1
Journal article Open

Fuzzy Mathematical Analysis of Blood flow through Brachial Artery

  • 1. International School, Lahore

Description

Hypertension is a common disease that can be caused by a number of factors. Antidepressants. A variety of methods, including Doppler Ultrasonography, can be used to detect hypertension, which is aided by High Blood Pressure. The fuzzy logic approach is ideal for combining human expert knowledge with pre-existing numerical data. Fuzzy logic systems use human reasoning and decision-making to generate reliable output even when precise information is unavailable. In the case of biological systems, mathematical modelling is extremely complex, but fuzzy linguistic rules have been shown to aid in the resolution of complexity.

Files

PJEST-013-GICCL-21(1).pdf

Files (584.9 kB)

Name Size Download all
md5:bd13082394df04582060469b02195ac2
584.9 kB Preview Download

Additional details

References

  • [1] J. H. Southerland, D. G. Gill, P. R. Gangula, L. R. Halpern, C. Y. Cardona, C. P. J. C. Mouton, cosmetic, et al., "Dental management in patients with hypertension: challenges and solutions," vol. 8, p. 111, 2016. [2] A. Ganau, R. B. Devereux, M. J. Roman, G. De Simone, T. G. Pickering, P. S. Saba, et al., "Patterns of left ventricular hypertrophy and geometric remodeling in essential hypertension," vol. 19, pp. 1550-1558, 1992. [3] R. H. Rao, U. B. Rao, S. J. C. Srikantia, and e. hypertension, "Effect of polyunsaturate-rich vegetable oils on blood pressure in essential hypertension," vol. 3, pp. 27-38, 1981. [4] I. B. Puddey, L. J. J. C. Beilin, E. Pharmacology, and Physiology, "Alcohol is bad for blood pressure," vol. 33, pp. 847-852, 2006. [5] B. Kheiri, A. Abdalla, M. Osman, S. Ahmed, M. Hassan, and G. J. C. h. Bachuwa, "Vitamin D deficiency and risk of cardiovascular diseases: a narrative review," vol. 24, pp. 1-9, 2018. [6] R. S. Cooper, C. N. Rotimi, and R. J. S. A. Ward, "The puzzle of hypertension in African-Americans," vol. 280, pp. 56-63, 1999. [7] S. F. Rimoldi, U. Scherrer, and F. H. J. E. h. j. Messerli, "Secondary arterial hypertension: when, who, and how to screen?," vol. 35, pp. 1245-1254, 2014. [8] G. Pitter, M. Zare Jeddi, G. Barbieri, M. Gion, A. S. Fabricio, F. Daprà, et al., "Perfluoroalkyl substances are associated with elevated blood pressure and hypertension in highly exposed young adults," vol. 19, pp. 1-11, 2020. [9] A. Blenkinsopp, M. Duerden, and J. Blenkinsopp, Symptoms in the pharmacy: a guide to the management of common illnesses: John Wiley & Sons, 2018. [10] Y. Li, F.-F. Wei, S. Wang, Y.-B. Cheng, and J.-G. J. C. h. r. Wang, "Cardiovascular risks associated with diastolic blood pressure and isolated diastolic hypertension," vol. 16, p. 489, 2014. [11] E. A. Ashley and J. Niebauer, "Cardiology explained," 2004. [12] T. Skarpengland, M. Skjelland, X. Y. Kong, K. Skagen, S. Holm, K. Otterdal, et al., "Increased levels of lectin‐like oxidized low‐density lipoprotein receptor‐1 in ischemic stroke and transient ischemic attack," vol. 7, p. e006479, 2018. [13] C. Lomonte, F. Casucci, M. Antonelli, B. Giammaria, N. Losurdo, G. Marchio, et al., "Is there a place for duplex screening of the brachial artery in the maturation of arteriovenous fistulas?," in Seminars in dialysis, 2005, pp. 243-246. [14] H. L. Cogswell, Water birds of California vol. 40: Univ of California Press, 1977. [15] A. A. DiSessa, Changing minds: Computers, learning, and literacy: Mit Press, 2001. [16] E. I. Galanzha, Y. A. Menyaev, A. C. Yadem, M. Sarimollaoglu, M. A. Juratli, D. A. Nedosekin, et al., "In vivo liquid biopsy using Cytophone platform for photoacoustic detection of circulating tumor cells in patients with melanoma," vol. 11, 2019. [17] I. K. Ekroll, A. Swillens, P. Segers, T. Dahl, H. Torp, L. J. I. t. o. u. Lovstakken, ferroelectrics,, et al., "Simultaneous quantification of flow and tissue velocities based on multi-angle plane wave imaging," vol. 60, pp. 727-738, 2013. [18] O. Ginther and M. D. J. J. o. E. V. S. Utt, "Doppler ultrasound in equine reproduction: principles, techniques, and potential," vol. 24, pp. 516-526, 2004. [19] E. J. Halpern, D. A. Merton, and F. J. R. Forsberg, "Effect of distal resistance on Doppler US flow patterns," vol. 206, pp. 761-766, 1998. [20] N. de Riva, K. P. Budohoski, P. Smielewski, M. Kasprowicz, C. Zweifel, L. A. Steiner, et al., "Transcranial Doppler pulsatility index: what it is and what it isn't," vol. 17, pp. 58-66, 2012. [21] M. Klarhöfer, B. Csapo, C. Balassy, J. Szeles, and E. Moser, "High‐resolution blood flow velocity measurements in the human finger," Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine, vol. 45, pp. 716-719, 2001. [22] D. A. Christopher, P. N. Burns, B. G. Starkoski, and F. S. Foster, "A high-frequency pulsed-wave Doppler ultrasound system for the detection and imaging of blood flow in the microcirculation," Ultrasound in medicine & biology, vol. 23, pp. 997-1015, 1997. [23] T. S. Hong, D. Nakhaeinia, B. J. F. L.-C. Karasfi, Concepts, Theories, and Applications, "Application of fuzzy logic in mobile robot navigation," pp. 21-36, 2012. [24] M. Erman, A. Mohammed, and E. Rakus-Andersson, "Fuzzy Logic Applications in Wireless Communications," in IFSA/EUSFLAT Conf., 2009, pp. 763-767. [25] M. Mahfouf, M. F. Abbod, and D. A. J. A. i. i. m. Linkens, "A survey of fuzzy logic monitoring and control utilisation in medicine," vol. 21, pp. 27-42, 2001. [26] S. Tayyaba, M. J. Afzal, G. Sarwar, M. W. Ashraf, and N. Afzulpurkar, "Simulation of flow control in straight microchannels using fuzzy logic," in 2016 International Conference on Computing, Electronic and Electrical Engineering (ICE Cube), 2016, pp. 213-216. [27] M. J. Afzal, S. Tayyaba, M. W. Ashraf, M. K. Hossain, M. J. Uddin, and N. J. M. Afzulpurkar, "Simulation, fabrication and analysis of silver based ascending sinusoidal microchannel (ASMC) for implant of varicose veins," vol. 8, p. 278, 2017. [28] M. J. Afzal, M. W. Ashraf, S. Tayyaba, M. K. Hossain, and N. J. M. Afzulpurkar, "Sinusoidal Microchannel with Descending Curves for Varicose Veins Implantation," vol. 9, p. 59, 2018. [29] M. W. Ashraf, S. Manzoor, M. Shahzad Sarfraz, M. F. Wasim, B. Ali, M. Akhlaq, et al., "Fabrication and fuzzy analysis of AAO membrane with manipulated pore diameter for applications in biotechnology," vol. 38, pp. 5857-5864, 2020. [30] M. Yasin, D. Afzal, B. Cornel, M. Balas, E. D. S. Tayyaba, and M. Ashrf, "Fuzzy parametric estimation of curvilinear microchannel for retinal vein occlusion (RVO)," ed, 2021. [31] S. Akkurt, G. Tayfur, and S. Can, "Fuzzy logic model for the prediction of cement compressive strength," Cement and Concrete Research, vol. 34, pp. 1429-1433, 08/01 2004. [32] T. Nawrocki, "The use of fuzzy logic in corporate innovative potential assessment," Econometrics, vol. 23, pp. 29-44, 01/01 2019. [33] P. J. MacVicar-Whelan, "Fuzzy sets for man-machine interaction," International Journal of Man-Machine Studies, vol. 8, pp. 687-697, 11/01 1976. [34] D. Afzal, F. Javaid, E. D. S. Tayyaba, M. Ashrf, and M. Hossain, Study on the Induced Voltage in Piezoelectric Smart Material (PZT) Using ANSYS Electric & Fuzzy Logic Study on the Induced Voltage in Piezoelectric Smart Material (PZT) Using ANSYS Electric & Fuzzy Logic vol. 6, 2020. [35] D. Afzal, E. D. S. Tayyaba, and M. Ashrf, "Simulation of a Nanoneedle for Drug Delivery by Using MATLAB Fuzzy Logic," Biologia (Lahore, Pakistan), vol. 64(1), p. 75, 08/02 2018. [36] D. Afzal, E. D. S. Tayyaba, M. Ashrf, and N. Afzulpurkar, Fluidic Simulation of J Shaped Channel, 2017.