Info: Zenodo’s user support line is staffed on regular business days between Dec 23 and Jan 5. Response times may be slightly longer than normal.

Published June 30, 2021 | Version v1
Journal article Open

Early Fault Detection by Vibration Measurement

  • 1. Graduate Student, Dept. of Production Engineering and Mechanical Design, Faculty of Engineering, Menoufia University, Shebin El-Kom, Egypt
  • 2. Dept. Production Engineering and Mechanical Design, Faculty of Engineering, Menoufia University, Shebin El-Kom, Egypt.
  • 3. Professor, Dr., Dept. of Production Engineering and Mechanical Dwsign, Faculty of Engineering, Menoufia University, Shebin El-Kom, Egypt.
  • 1. Publisher

Description

Early fault detection by using vibration monitoring devices could help industries to avoid sudden stoppage of the machine, thus reduces machine downtime and maintenance cost to save time and money. Early fault detection by using vibration measurement devices are very useful for determining the condition of rotating elements and its analysis. In this paper, experimental studies were performed to predict misalignment faults in rotating machine which is connected with simple rigid coupling. The vibration is collected by using Microlog data collector. From results, we can easily predict misalignment in rotating machine using spectrum analysis technique.

Files

E28170610521.pdf

Files (896.1 kB)

Name Size Download all
md5:dd6d7530225b46089a0ae0c648064e61
896.1 kB Preview Download

Additional details

Related works

Is cited by
Journal article: 2249-8958 (ISSN)

Subjects

ISSN
2249-8958
Retrieval Number
100.1/ijeat.E28170610521