ACDC converterTest3
Description
One AC/DC converter for EV applications was tested. An electronic load (Chroma 63200A 150V 600A) was used as DC load for testing. During the Test 3, the electronic load was set in a constant resistant mode and at 5 Ω. The output voltage of the AC/DC converter is set to 100 V, the resulting current is 20 A.
8 files are uploaded related to this test.
Raw Voltage, Raw Current, Voltage Harmonics, respectivley Current Harmonics. The results of the harmonics emissions are provided as Peak, Average and Quasi peak values.
There are 4 data files and, respectivley, their associated 4 info files.
Notes
Files
ACDC converterTest3_rawCurrentL1_Data_V1.csv.csv
Files
(210.4 MB)
Name | Size | Download all |
---|---|---|
md5:7a8438d41df2c985461a42714585a979
|
241.9 kB | Download |
md5:affb93d0076993ad427528932f505e5c
|
26.8 kB | Download |
md5:52f7d50969b8e7dcc273b9ab841bcc7e
|
109.9 MB | Preview Download |
md5:d2e8e02a3d3108826d9788dbb7a76d58
|
26.6 kB | Download |
md5:9b1e2f3c4d74c938655b1d65b065970d
|
100.0 MB | Preview Download |
md5:2c033dc62176cdc637dd9bdc6e37a839
|
26.4 kB | Download |
md5:81f5c8c897c2b8bd8f0af99ff93caf89
|
221.1 kB | Download |
md5:be03e32af63bbbd0f7ce851e33518b6c
|
26.7 kB | Download |