Published June 30, 2020 | Version v1
Preprint Open

Filter Transients onboard DC Rolling Stock and Exploitation for the Estimate of the Line Impedance

  • 1. ASTM
  • 2. Inrim
  • 3. Università degli Studi della Campania: Luigi Vanvitelli
  • 4. Politecnico di Torino, Inrim

Description

Power supply transients in dc railways related to
filter charging may trigger network and filter oscillatory responses, as well as cause very fast voltage spikes. These phenomena are relevant not only for Power Quality and EMC, but also for their impact on the measured pantograph quantities e.g. for power and energy consumption estimate. The broadband excitation of the system gives the possibility of attempting the identification of the network impedance. The experimental results are discussed and compared to the output of a circuit and a distributed parameter simulator. Matching between simulated and experimental data is very good

Files

Filter Transient onboard DC Rolling Stock and Exploitation for the Estimate of the Line Impedance.pdf