Dataset Restricted Access

Aging Test - Cylindrical Cell - Part 01 - Single Cells

Juarez Robles, Daniel; Jeevarajan, Judith A.; Mukherjee, Partha P.

Thesis supervisor(s)

Mukherjee, Partha P.; Jeevarajan, Judith A.

Test Sample Specifications

  • Nominal Capacity = 3400 mAh
  • Graphite / NCA 
  • 18650 Cell 

Cycling Protocol - Normal (N) Voltage Window

  • Charge: CCCV at C/2 up to 4.2 V and a 50 mA cutoff current 
  • Discharge: CC at C/2 down to 2.7 V

Cycling Protocol - Reduced (R) Voltage Window

  • Charge: CCCV at C/2 up to 4.0 V and a 50 mA cutoff current 
  • Discharge: CC at C/2 down to 2.9 V

Cycling Life

Capacity fade and number of cycles are included in the filename.

Example:

  • File = 'Ba01_N20_OV1_300.xls'
  • N20 = 20% Capacity fade under the normal voltage window
  • Number of Cycles = 300
N stands for normal voltage window R stands for reduced voltage window OV indicates the cell was overcharged at the end of the aging test EX indicates the cell was externally shorted at the end of the aging test
Restricted Access

You may request access to the files in this upload, provided that you fulfil the conditions below. The decision whether to grant/deny access is solely under the responsibility of the record owner.


To access the files, send an email to NFP.BatterySafety@ul.org

Website: Underwriters Laboratories Inc.


776
187
views
downloads
All versions This version
Views 776776
Downloads 187187
Data volume 1.7 GB1.7 GB
Unique views 637637
Unique downloads 2121

Share

Cite as