Thiosulfonylation of Unactivated Alkenes with Visible-Light Organic Photocatalysis
Authors/Creators
- 1. Division of Organic Synthesis, Department of Chemistry, University of Antwerp
- 2. Biophysics and Biomedical Physics (BIMEF), Department of Chemistry, University of Antwerp
- 3. Molecular Spectroscopy, Department of Chemistry, University of Antwerp
Description
Origin of the data: Experimental spectroscopic measurements
Data Type: experimental measurements, open access supporting information
The data are in CSV, DSW and FBSW format. Supporting information are supplied in PDF format.
Data generated by instruments:
Varian Cary 5E-UV-Vis-NIR spectrophotometer for UV-Vis measurements,
Varian Cary Eclipse fluorescence spectrophotomer for fluorescence quenching measurements.
Analytical and procedural information: Stern-Volmer fluorescence quenching experiments, UV-Vis measurements and Fluorescent Quantum Yield determination via ferrioxalate actinometry.
Definition of variables: Wavelength, Absorbance, Concentration
Units of measurement: nanometers (nm), moles-per-litre (mol/l)
Abbreviations:
File names and data headers use the following abbreviations:
- FQY refers to Fluorescence Quantum Yield determination experiments
- Light refers to irradiated samples in the actinometry experiment, as detailed in the procedure in the supporting information.
- Dark refers to non-irradiated samples in the actinometry experiment, as detailed in the procedure in the supporting information.
- SVQuench refers to Stern-Volmer quenching experiments
- RAxx refer to measurements related to allylbenzene. Xx is the amount of quencher in mol/l (05 should be intended as 0.5 mol/l and so on).
- RTxx refer to measurements related to S-(4-methylphenyl) 4-methylbenzenethiosulfonate. Xx is the amount of quencher in mol/l as above.
- RExx refer to measurements related to 1,2-dimethoxy-4-(prop-2-en-1-yl)benzene. Xx is the amount of quencher in mol/l as above.
- RSxx refer to measurements related to styrene. Xx is the amount of quencher in mol/l.
- RTFxx refer to measurements related to S-(4-fluorophenyl) 4-fluorobenzenethiosulfonate. Xx is the amount of quencher in mol/l as above.
- MesAcrMe Xx refers to data related to catalyst 9-mesityl-10-methylacridinium. Xx is the amount of catalyst in mol/l as above.
- DMC for measurements employing dimethylcarbonate as solvent.
- ACN for measurements employing acetonitrile as solvent.
Notes
Files
PARACAT_WP5_20201028_FQYDetermination.zip
Files
(266.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:19b72138ccc4c58244f86be591852d0e
|
266.7 kB | Preview Download |
Additional details
Related works
- Is cited by
- Journal article: 10.1021/acscatal.0c02159 (DOI)