Published June 23, 2020 | Version v1

Thiosulfonylation of Unactivated Alkenes with Visible-Light Organic Photocatalysis

  • 1. Division of Organic Synthesis, Department of Chemistry, University of Antwerp
  • 2. Biophysics and Biomedical Physics (BIMEF), Department of Chemistry, University of Antwerp
  • 3. Molecular Spectroscopy, Department of Chemistry, University of Antwerp

Description

Origin of the data: Experimental spectroscopic measurements
Data Type: experimental measurements, open access supporting information

The data are in CSV, DSW and FBSW format. Supporting information are supplied in PDF format.

Data generated by instruments:  

Varian Cary 5E-UV-Vis-NIR spectrophotometer for UV-Vis measurements,
Varian Cary Eclipse fluorescence spectrophotomer for fluorescence quenching measurements.

Analytical and procedural information: Stern-Volmer fluorescence quenching experiments, UV-Vis measurements and Fluorescent Quantum Yield determination via ferrioxalate actinometry.

Definition of variables: Wavelength, Absorbance, Concentration
Units of measurement: nanometers (nm), moles-per-litre (mol/l)

Abbreviations:
File names and data headers use the following abbreviations:

  • FQY refers to Fluorescence Quantum Yield determination experiments
  • Light refers to irradiated samples in the actinometry experiment, as detailed in the procedure in the supporting information.
  • Dark refers to non-irradiated samples in the actinometry experiment, as detailed in the procedure in the supporting information.
  • SVQuench refers to Stern-Volmer quenching experiments
  • RAxx refer to measurements related to allylbenzene. Xx is the amount of quencher in mol/l (05 should be intended as 0.5 mol/l and so on).
  • RTxx refer to measurements related to S-(4-methylphenyl) 4-methylbenzenethiosulfonate. Xx is the amount of quencher in mol/l as above.
  • RExx refer to measurements related to 1,2-dimethoxy-4-(prop-2-en-1-yl)benzene. Xx is the amount of quencher in mol/l as above.
  • RSxx refer to measurements related to styrene. Xx is the amount of quencher in mol/l.
  • RTFxx refer to measurements related to S-(4-fluorophenyl) 4-fluorobenzenethiosulfonate. Xx is the amount of quencher in mol/l as above.
  • MesAcrMe Xx refers to data related to catalyst 9-mesityl-10-methylacridinium. Xx is the amount of catalyst in mol/l as above.
  • DMC for measurements employing dimethylcarbonate as solvent.
  • ACN for measurements employing acetonitrile as solvent.

Notes

FBSW and DSW data are used by the proprietary software of the Varian spectrometers (CARY WinUV and Cary Eclipse). Information can be found at https://www.agilent.com/en/product/molecular-spectroscopy/uv-vis-uv-vis-nir-spectroscopy/uv-vis-uv-vis-nir-software/cary-winuv-software and https://www.agilent.com/en/product/molecular-spectroscopy/fluorescence-spectroscopy/fluorescence-software/cary-eclipse-software

Files

PARACAT_WP5_20201028_FQYDetermination.zip

Files (266.7 kB)

Name Size Download all
md5:19b72138ccc4c58244f86be591852d0e
266.7 kB Preview Download

Additional details

Related works

Is cited by
Journal article: 10.1021/acscatal.0c02159 (DOI)

Funding

European Commission
PARACAT - Paramagnetic Species in Catalysis Research. A Unified Approach Towards Heterogeneous, Homogeneous and Enzyme Catalysis 813209