Info: Zenodo’s user support line is staffed on regular business days between Dec 23 and Jan 5. Response times may be slightly longer than normal.

Published September 1, 2020 | Version v1
Journal article Open

Parameters observation of restoration capacity of industrial lead acid battery using high current pulses

  • 1. Universiti Tun Hussein Onn Malaysia
  • 2. Renewcell (M) Sdn Bhd

Description

Batteries play an essential role on most of the electrical equipment and electrical engineering tools. However, one of the drawbacks of lead acid batteries is PbSO4 accumulates on the battery plates, which significantly cause deterioration. Therefore, this study discusses the discharge capacity performance evaluation of the industrial lead acid battery. The selective method to improve the discharge capacity is using high current pulses method. This method is performed to restore the capacity of lead acid batteries that use a maximum direct current (DC) of up to 500 A produces instantaneous heat from 27°C to 48°C to dissolve the PbSO4 on the plates. This study uses an 840 Ah, 36 V flooded lead acid batteries for a forklift for the evaluation test. Besides, this paper explores the behavior of critical formation parameters, such as the discharge capacity of the cells. From the experimental results, it can be concluded that the discharge capacity of the flooded lead acid battery can be increase by using high current pulses method. The comparative findings for the overall percentage of discharge capacity of the batteries improved from 68% to 99% after the restoration capacity.

Files

52 20816 2020.pdf

Files (257.2 kB)

Name Size Download all
md5:59b1aab3232a45dd5ead8c8f50837661
257.2 kB Preview Download