There is a newer version of the record available.

Published June 1, 2018 | Version preprint

STAPP: Spatiotemporal analysis of plantar pressure measurements using statistical parametric mapping

  • 1. University of Antwerp
  • 2. Sint Maartenskliniek
  • 3. Delft University of Technology

Description

Background

Pedobarography produces large sets of plantar pressure samples that are routinely subsampled (e.g. using regions of interest) or aggregated (e.g. center of pressure trajectories, peak pressure images) in order to simplify statistical analysis and provide intuitive clinical measures.

Research question

We hypothesize that these data reductions discard gait information that can be used to differentiate between groups or conditions.

Methods

To test the hypothesis of null information loss, we created an implementation of statistical parametric mapping (SPM) for dynamic plantar pressure datasets (i.e. plantar pressure videos). Our SPM software framework brings all plantar pressure videos into anatomical and temporal correspondence, then performs statistical tests at each sampling location in space and time. Novelly, we introduce non-linear temporal registration into the framework in order to normalize for timing differences within the stance phase. We refer to our software framework as STAPP: spatiotemporal analysis of plantar pressure measurements. Using STAPP, we tested our hypothesis on plantar pressure videos from 33 healthy subjects walking at different speeds.

Results

As walking speed increased, STAPP was able to identify significant decreases in plantar pressure at mid-stance from the heel through the lateral forefoot. The extent of these plantar pressure decreases has not previously been observed using existing plantar pressure analysis techniques.

Significance

We therefore conclude that the subsampling of plantar pressure videos – a task which led to the discarding of gait information in our study – can be avoided using STAPP.

Notes

This research has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement no. 746614.

Files

STAPP.pdf

Files (1.1 MB)

Name Size
md5:7d42ad5e222054f19a14880722b4a586
1.1 MB Preview Download

Additional details

Funding

European Commission
CAD WALK - CAD WALK: Enabling Computer Aided Diagnosis of Foot Pathologies through the use of Metric Learning 746614