Published August 27, 2024 | Version 1.0

ENDGAME - Laboratory Experiment 2024-03-21 Exp. 019 - High Speed Camera data

Description

Shock-tube experiments in combination with high speed Schlieren shadow photography. 

The shocktube setup consists of a high-pressure reservoir connected with a cylindrical tube through a diaphragm pulse valve which allows a fast release of pressurized gas into the ambient pressure tube. The high-pressure reservoir is filled with compressed air at a given overpressure with respect to ambient pressure (up to 8 bar). The pipe was either empty (i.e. with air at ambient conditions) or filled with a given amount of small particles. We adopted a pipe with an inner diameter of 4 cm (outer diameter 5 cm) and 80 cm long. The volume of pressurized gas injected into the pipe was ~3000 cm3. In some cases a pressure sensor has been placed at the vent of the conduit to record pressure variations during the experiment. Images from the high speed camera were collected at a frame rate of 30000 fps.

When the valve is open, a jet flow is produced, with shock and acoustic waves propagating in the atmosphere, which become visible due to the high speed Schlieren shadow photography.

Files

ENDGAME_LabExp_HighSpeedCamera_20240321_019.zip

Files (1.2 GB)

Name Size
md5:3ff2ac5b4c4dbdc6d8caf8ec6a48993f
759.2 MB Preview Download
md5:c111f0fd7dcf1b1f19ce2215a0a9729a
453.2 MB Preview Download

Additional details

Funding

European Commission
ENDGAME - laboratory Experiments, Numerical moDellinG and field observAtions of basaltic Magma fragmEntation 101025887