Human arm joints reconstruction algorithm in rehabilitation therapies assisted by end-effector robotic devices

  • 1. Miguel Hernández University of Elche, Av. Universidad w/n, Ed. Innova, Elche, 03202, Spain
  • 2. Universidad de Cadiz, Avenida de la Universidad n 10, Puerto Real, 11519, Spain
  • 3. Research Unit of Biomedical Robotics and Biomicrosystems, Università Campus Bio-Medico di Roma, via Álvaro del Portillo, 21, Roma, 00128, Italy

Description

Background: End-effector robots are commonly used in robot-assisted neuro-rehabilitation therapies for upper limbs where the patient's hand can be easily attached to a splint. Nevertheless, they are not able to estimate and control the kinematic configuration of the upper limb during the therapy. However, the Range of Motion (ROM) together with the clinical assessment scales offers a comprehensive assessment to the therapist. Our aim is to present a robust and stable kinematic reconstruction algorithm to accurately measure the upper limb joints using only an accelerometer placed onto the upper arm.

Methods: The proposed algorithm is based on the inverse of the augmented Jaciobian as the algorithm (Papaleo, et al., Med Biol Eng Comput 53(9):815–28, 2015). However, the estimation of the elbow joint location is performed through the computation of the rotation measured by the accelerometer during the arm movement, making the algorithm more robust against shoulder movements. Furthermore, we present a method to compute the initial configuration of the upper limb necessary to start the integration method, a protocol to manually measure the upper arm and forearm lengths, and a shoulder position estimation. An optoelectronic system was used to test the accuracy of the proposed algorithm whilst healthy subjects were performing upper limb movements holding the end effector of the seven Degrees of Freedom (DoF) robot. In addition, the previous and the proposed algorithms were studied during a neuro-rehabilitation therapy assisted by the 'PUPArm' planar robot with three post-stroke patients.

Results: The proposed algorithm reports a Root Mean Square Error (RMSE) of 2.13cm in the elbow joint location and 1.89cm in the wrist joint location with high correlation. These errors lead to a RMSE about 3.5 degrees (mean of the seven joints) with high correlation in all the joints with respect to the real upper limb acquired through the optoelectronic system. Then, the estimation of the upper limb joints through both algorithms reveal an instability on the previous when shoulder movement appear due to the inevitable trunk compensation in post-stroke patients.

Conclusions: The proposed algorithm is able to accurately estimate the human upper limb joints during a neuro-rehabilitation therapy assisted by end-effector robots. In addition, the implemented protocol can be followed in a clinical environment without optoelectronic systems using only one accelerometer attached in the upper arm. Thus, the ROM can be perfectly determined and could become an objective assessment parameter for a comprehensive assessment.

Files

12984_2018_348_MOESM1_ESM.pdf

Files (2.3 MB)

Name Size Download all
md5:b3f0be99debddb6b0c465632619b46ba
107.5 kB Preview Download
md5:31a6031df59b9a8dd6a51689297c889d
109.9 kB Preview Download
md5:69a007dab93348a9c4a78d44b1943465
2.1 MB Preview Download
md5:266eb48ab3533dc191ddcb917143dcbf
17.9 kB Download

Additional details

Funding

ECHORD PLUS PLUS – European Clearing House for Open Robotics Development Plus Plus 601116
European Commission