Published February 6, 2022 | Version v1
Dataset Open

IODP Expedition 378 Natural gamma radiation

Description

Natural gamma radiation (NGR) data in the ~0.1 to 3.0 MeV range were measured using eight custom-designed sodium iodide (thallium) [NaI(Tl)] detectors arranged along the core measurement axis at 20 cm intervals. The NGR system uses layers of passive shielding (lead) and active shielding (plastic scintillators and coincidence electronics) to reduce the cosmic-ray signal for low-count analysis of sediment core sections and to obtain the maximum signal-to-noise ratio. Data are reported on a total counts per second basis and the raw spectral files are available as compressed files for later analysis.

Files

NGR-README.txt

Files (49.0 MB)

Name Size Download all
md5:12df3842e6b20f0af42efda961d4ddd6
525 Bytes Download
md5:6db36d28fc05749d622f942ad476523e
160.9 kB Preview Download
md5:6b5313579550e0f32ece227e08e3d9ca
185.5 kB Preview Download
md5:d57b7ab3254f81bf8b9d82526ffdfa8b
161.6 kB Preview Download
md5:15595fe9d28f120ad30bfaaacd30d4ac
77.8 kB Preview Download
md5:1d47fc8ed07df51bf564ba5cca813efe
2.2 kB Preview Download
md5:33838fe3608deb1b225903e03eaf4056
48.4 MB Preview Download

Additional details

Related works

Is documented by
Publication: 10.14379/iodp.proc.378.2022 (DOI)

Funding

Management and Operations of the JOIDES Resolution as a Facility for the International Ocean Discovery Program (IODP) 1326927