Published October 1, 2023 | Version preprint

Microneedle array-based electrochemical sensor functionalized with nanomaterials for the highly sensitive monitoring of MDMA in interstitial fluid

  • 1. Department of Analytical Chemistry; A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium; , Faculty of Pharmacy, 'Iuliu Hațieganu' University of Medicine and Pharmacy Cluj-Napoca, Pasteur 6, 400349 Cluj-Napoca, Romania
  • 2. A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
  • 3. NANOrOPT, Department of Physics, University of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
  • 4. School of Pharmacy, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, United Kingdom; Department of Pharmacy and Pharmaceutical Technology, University of Seville, 41012 Seville, Spain
  • 5. School of Pharmacy, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, United Kingdom
  • 6. Department of Analytical Chemistry, Faculty of Pharmacy, 'Iuliu Hațieganu' University of Medicine and Pharmacy Cluj-Napoca, Pasteur 6, 400349 Cluj-Napoca, Romania

Description

Herein, we report the development of a wearable electrochemical platform based on a hollow microneedle (MN) array-based sensor for the monitoring of MDMA in the interstitial fluid by square-wave voltammetry. First, the holes of the MN array were modified with conductive pastes to devise a MN patch with a three-electrode system. Subsequently, the functionalization of the working electrode with nanomaterials enhanced MDMA detection. Thereafter, analytical parameters were evaluated exhibiting a slope of 0.05 μA μM-1 within a linear range from 1 to 50 μM and a limit of detection of 0.75 μM in artificial interstitial fluid. Importantly, critical parameters such as selectivity, piercing capability, temperature, reversibility and stability were assessed. Overall, the obtained MN sensor exhibited excellent analytical performance, making it a promising tool for MDMA tracking in interstitial fluid for individuals on probation or under therapeutic treatment.

Files

MDMA MNs manuscript_preprint.pdf

Files (1.1 MB)

Name Size
md5:a016185683e12bc85c6ee08fe94ab910
1.1 MB Preview Download

Additional details

Funding

European Commission
BorderSens - Border detection of illicit drugs and precursors by highly accurate electrosensors 833787