Ultrasonic Pulse Transmission Tests: Datasets - Test Series 7, Reference Tests on Aluminium Cylinder
Description
The test series was created in order to validate the stability and functionality of the test device and to create a data reference for metals (aluminium cylinder). The approach for the test series was to vary the parameters number-of-samples-recorded and pulse-voltage. This results in a two-dimensional test parameter grid. Tests were performed several times for each grid point (number-of-samples-recorded versus pulse-voltage) in order to receive statistical information about the stability of the test results. The material tested was an aluminium cylinder with a diameter of 50 millimetres and a height of 50 millimetres. The test method used was the ultrasonic pulse transmission method with combined compression- and shear wave measurements. All test data and metadata are summarized into datasets using GNU Octave's open binary file format.
Notes
Files
ts7_techdescr.pdf
Files
(49.0 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:32559e40ae3f6ef1a181a6b254813ea8
|
10.2 MB | Download |
|
md5:f3ed4fa9564861bece909a0312c6fa08
|
38.4 MB | Download |
|
md5:a7f4114aabc0a3383f59e2e358bb9b49
|
330.1 kB | Preview Download |
Additional details
Related works
- Is described by
- Preprint: 10.31224/4465 (DOI)
- Preprint: 10.20944/preprints202503.2008.v1 (DOI)
- Is previous version of
- Dataset: 10.3217/W3MB5-1WX17 (DOI)
Dates
- Updated
-
2025-10-14added references to preprints