Published March 10, 2023 | Version PDF
Journal article Open

Comparative Evaluation of Shear Bond Strength of Cention N and Glass Ionomer Cement - An In Vitro Study

  • 1. 1BDS, SJM Dental College and Hospital, Chitradurga, Karnataka, India
  • 2. BDS, Guru Nanak Dev Dental College and Research Institute, Sunam, Punjab, India
  • 3. BDS, Sudha Rustagi College of Dental Sciences and Research, Faridabad, India

Description

Aim: This study compared the shear bond strengths of glass-ionomer cement (GIC) Type IX and Cention N.
Materials and Methods: To assess the shear bond strength, 40 samples each of GIC Type IX and Cention N were evaluated. Sample cylinders with dimensions of 4 mm in diameter and 4 mm in height were bonded to the buccal surface of teeth to evaluate the shear bond strength in a universal testing machine with a crosshead speed of 1 mm/min.
Results: The shear bond strength of Cention N in comparison to GIC Type IX was statistically highly significant (P < 0.01).
Conclusion: The results reached to a conclusion that shear bond strength of Cention N as compared to GIC Type IX was superior.

Files

SVOA-DE-04-0122.pdf

Files (300.8 kB)

Name Size Download all
md5:28fc7a72e6cc53276711ebea902b8eff
300.8 kB Preview Download