In vitro four-dimensional flow magnetic resonance analysis of the effect of pericardial valve design on aortic flow

  • 1. Cardiac Surgery Department, Heart Health Center, King Saud Medical City, Riyadh, Kingdom of Saudi Arabia.
  • 2. 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • 3. Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • 4. Siemens Healthcare GmbH, Erlangen, Germany.
  • 5. Cardiac Surgery Department, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • 6. Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy.

Description

Tasca G, Sturla F, Jaworek M, Giese D, Menicanti L, Vismara R, Lombardi M, Redaelli A. In vitro four-dimensional flow magnetic resonance analysis of the effect of pericardial valve design on aortic flow. J Med Eng Technol. 2022 Apr;46(3):209-219. doi: 10.1080/03091902.2022.2026505. Epub 2022 Jan 21. PMID: 35060819.

Abstract

We investigated the effect of the design of bioprosthetic pericardial valves on the downstream fluid flow pattern through four-dimensional flow magnetic resonance imaging (4D Flow). A dedicated in vitro test bench, including a paradigmatic aortic root phantom, was used to compare, under steady flow conditions, three commercially used pericardial bioprostheses (TrifectaTM, Carpentier-Edwards PERIMOUNT Magna, Crown PRT®), selecting the two smallest and comparable valve sizes. In-house 4D Flow post-processing provided the downstream flow pattern of velocity, the velocity profile at vena contracta, its effective orifice area (EOA) and the corresponding hydraulic diameter (DH). Trifecta reported the lowest peak of velocity for both the tested sizes, with vena contracta position being the most proximal to the free margin of leaflets. Conversely, in both Crown and Magna, jet flow continued to increase its downstream velocity, resulting in a farther position of vena contracta. EOA shape was trilobal for Magna, triangular for Crown and circular for Trifecta, the last one maximising EOA. The percentage of nominal luminal area effectively exploited by the flow was largely above 80% in Trifecta, below 75% in Crown and below 70% in Magna. Hence, the design of pericardial bioprostheses directly impacts on the downstream flow field pattern and its fluid dynamic performance.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

These data are available upon duly motivated request to the corresponding author of the article

You are currently not logged in. Do you have an account? Log in here