Justifying parameters for the automatic servo control system of a rotary plate vacuum pump in the milking machine
Authors/Creators
- 1. Dnipro State Agrarian and Economic University, Ukraine
- 2. State Biotechnological University, Ukraine
- 3. National Scientific Center «Institute of Experimental and Clinical Veterinary Medicine», Ukraine
- 4. Sumy National Agrarian University, Ukraine
Description
The scientific task to improve energy efficiency and ensure the process of vacuum regime stabilization in the operation of milking machines has been solved.
A mathematical model of the process of functioning of the servo control system of a rotary plate vacuum pump was built; the numerical modeling of its workflow was carried out.
This paper reports the results of experimental studies on the influence of the regime parameters of the rotary plate vacuum pump on the efficiency of its operation, as well as the results of experimental research on the servo control system for the rotary plate vacuum pump.
The operational process of the rotary plate vacuum pump HB-1200 for a milking machine was investigated. The influence of mode parameters (rotor speed n and vacuum pressure P) on the performance of the vacuum pump, Qa, vacuum pressure fluctuation, ΔP, and the power consumption of the vacuum pump drive, Np, has been determined.
The servo control system of the rotary plate vacuum pump was experimentally investigated based on the developed algorithms of its operation. In a generally accepted algorithm, vacuum fluctuation increases with increasing an airflow rate: at ΔQa=45 l/min – ΔP=2.3 kPa; at ΔQa=90 l/min – ΔP=4.6 kPa; at ΔQa=135 l/min – ΔP=6.4 kPa. Unlike the generally accepted one, the developed algorithm enables a stable vacuum mode with the largest vacuum fluctuation being ΔP=2.4 kPa.
For the first time, the functional dependence of the influence of the regime parameters of the rotary plate vacuum pump with its automatic servo control system on the stability of the vacuum regime of a milk-vacuum system in the milking machine was established.
The results can be applied when improving milking machines in terms of ensuring the stabilization process of the vacuum regime.
Files
Justifying parameters for the automatic servo control system of a rotary plate vacuum pump in the milking machine.pdf
Files
(1.2 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:d4b66dad164161fa3abe413512ae2977
|
1.2 MB | Preview Download |
Additional details
References
- Britt, J. H., Cushman, R. A., Dechow, C. D., Dobson, H., Humblot, P., Hutjens, M. F. et. al. (2018). Invited review: Learning from the future – A vision for dairy farms and cows in 2067. Journal of Dairy Science, 101(5), 3722–3741. doi: https://doi.org/10.3168/jds.2017-14025
- Tousova, R., Duchacek, J., Stadnik, L., Ptacek, M., Beran, J. (2014). The comparison of milk production and quality in cows from conventional and automatic milking systems. Journal of Central European Agriculture, 15 (4), 100–114. doi: https://doi.org/10.5513/jcea01/15.4.1515
- Shkromada, O., Skliar, O., Pikhtirova, A., Inessa, G. (2019). Pathogens transmission and cytological composition of cow's milk. Acta Veterinaria Eurasia. doi: https://doi.org/10.26650/actavet.2019.19004
- Nanka, O., Shigimaga, V., Paliy, A., Sementsov, V., Paliy, A. (2018). Development of the system to control milk acidity in the milk pipeline of a milking robot. Eastern-European Journal of Enterprise Technologies, 3 (9 (93)), 27–33. doi: https://doi.org/10.15587/1729-4061.2018.133159
- Medvedskyi, O., Achkevych, O., Achkevych, V. (2019). Dynamics of the vacuummetric pressure of the dairy chamber of the collector of milking machine. Scientific Horizons, 5 (78), 51–57. doi: https://doi.org/10.33249/2663-2144-2019-78-5-51-57
- Kubina, Ľ., Kováč, Š. (2002). Decreasing energetic demands of vacuum pumps being used in machine milking with utilization of a frequency convertor. Res. Agr. Eng., 48, 103–111.
- Pavlenko, S. I., Dudin, V. Yu., Aliiev, E. B. (2011). Optymizatsiya konstruktyvno-rezhymnykh parametriv rotatsiynoho vakuumnoho nasosu indyvidualnoi doilnoi ustanovky. Mekhanizatsiya, ekolohizatsiya ta konvertatsiya biosyrovyny v tvarynnytstvi: zb. nauk. prats In-tu mekh. tvarynnytstva NAAN, 1 (7), 133–144.
- Paliy, A., Aliiev, E., Paliy, A., Ishchenko, K., Lukyanov, I., Dobrovolsky, V. et. al. (2021). Revealing changes in the technical parameters of the teat cup liners of milking machines during testing and production conditions. EUREKA: Physics and Engineering, 6, 102–111. doi: https://doi.org/10.21303/2461-4262.2021.002056
- Odorčić, M., Rasmussen, M. D., Paulrud, C. O., Bruckmaier, R. M. (2019). Review: Milking machine settings, teat condition and milking efficiency in dairy cows. Animal, 13, s94–s99. doi: https://doi.org/10.1017/s1751731119000417
- Konovalov, O. V., Medvedskyi, O. V., Shapirenko, V. V. (2010). Doslidzhennia avtomatychnoi systemy rehuliuvannia vakuummetrychnoho tysku doilnykh ustanovok. Visnyk Zhytomyrskoho natsionalnoho ahroekolohichnoho universytetu, 2 (27), 172–177.
- Paliy, A., Aliiev, E., Paliy, A., Ishchenko, K., Shkromada, O., Musiienko, Y. et. al. (2021). Development of a device for cleansing cow udder teats and testing it under industrial conditions. Eastern-European Journal of Enterprise Technologies, 1 (1 (109)), 43–53. doi: https://doi.org/10.15587/1729-4061.2021.224927
- Kaskous, S. (2022). Laboratory Tests to Optimize the Milking Machine Settings with Air Inlet Teat Cups for Sheep and Goats. Dairy, 3 (1), 29–46. doi: https://doi.org/10.3390/dairy3010003
- Dudin, V. Yu., Plotnytskyi, V. I., Aliev, E. B. (2013). Eksperymentalni doslidzhennia faz rozpodilu povitria rotatsiinoho plastynchatoho vakuumnoho nasosa. Materiały IX Międzynarodowej naukowi-praktycznej konferencji «Perspektywiczne opracowania są nauką i technikami – 2013». Rolnictwo: Przemyśl. – Nauka i studia, 32, 24–27.
- Medvedskyi, O. V. (2015). Dynamika zminy tysku v obiemakh konstruktyvnykh elementiv vakuumnoi systemy mobilnoi doilnoi ustanovky. Naukovyi visnyk Natsionalnoho universytetu bioresursiv i pryrodokorystuvannia Ukrainy, 212, 161–167. URL: http://nbuv.gov.ua/UJRN/nvnau_tech_2015_212%282%29__24
- Lutsenko, M., Halai, O., Legkoduh, V., Lastovska, I., Borshch, O., Nadtochii, V. (2021). Milk production process, quality and technological properties of milk for the use of various types of milking machines. Acta Scientiarum. Animal Sciences, 43, e51336. doi: https://doi.org/10.4025/actascianimsci.v43i1.51336
- Aliev, E. (2012). Results of experimental investigations the vacuum of milk-milking equipment. Naukovyi visnyk Tavriyskoho derzhavnoho ahrotekhnolohichnoho universytetу, 2 (2), 108–115. URL: http://aliev.in.ua/doc/stat/2012/stat_7.pdf
- Medvedskyi, O. V., Bushma, S. V., Kukharets, S. M., Konovalov, O. V. (2014). Obgruntuvannia rezhymnykh kharakterystyk plastynchasto-rotornoho vakuumnoho nasosa dvostoronnoi diyi. Visnyk Zhytomyrskoho natsionalnoho ahroekolohichnoho universytetu, 1 (1 (39)), 197–203.
- Paliy, A., Aliiev, E., Nanka, A., Bogomolov, O., Bredixin, V., Paliy, A. et. al. (2021). Identifying changes in the technical parameters of milking rubber under industrial conditions to elucidate their effect on the milking process. Eastern-European Journal of Enterprise Technologies, 3 (1 (111)), 21–29. doi: https://doi.org/10.15587/1729-4061.2021.231917
- Khmelovskyi, V. (2020) Improving the design of a vacuum pump for milking units. Scientific journal «Engineering of nature management», 3 (17), 48–52. doi: https://doi.org/10.37700/enm.2020.3(17).48-52
- Dmytriv, V., Dmytriv, I., Borovets, V., Kachmar, R., Dmyterko, P., Horodetskyy, I. (2019). Analytical-experimental studies of delivery rate and volumetric efficiency of rotor-type vacuum pumps for milking machine. INMATEH – Agricultural Engineering, 58 (2), 57–62.
- Paliy, A., Nanka, A., Marchenko, M., Bredykhin, V., Paliy, A., Negreba, J. et. al. (2020). Establishing changes in the technical parameters of nipple rubber for milking machines and their impact on operational characteristics. Eastern-European Journal of Enterprise Technologies, 2 (1 (104)), 78–87. doi: https://doi.org/10.15587/1729-4061.2020.200635
- Besier, J., Bruckmaier, R. M. (2016). Vacuum levels and milk-flow-dependent vacuum drops affect machine milking performance and teat condition in dairy cows. Journal of Dairy Science, 99 (4), 3096–3102. doi: https://doi.org/10.3168/jds.2015-10340
- Paliy, A. P., Mashkey, A. M., Sumakova, N. V., Paliy, A. P. (2018). Distribution of poultry ectoparasites in industrial farms, farms, and private plots with different rearing technologies. Biosystems Diversity, 26 (2), 153–159. doi: https://doi.org/10.15421/011824
- Dmytriv, V. T., Dmytriv, I. V., Horodetskyy, I. M., Yatsunskyi, P. P. (2020). Adaptive cyber-physical system of the milk production process. INMATEH Agricultural Engineering, 61 (2), 199–208. doi: https://doi.org/10.35633/inmateh-61-22