Published June 11, 2026 | Version v2

Automatic Generation of Lumped Parameter Cardiovascular Physiology Model

  • 1. Clemson University

Description

This software will construct and run a realistic closed-loop lumped-parameter model of cardiovascular physiology.  The software automatically tunes the model parameters to achieve a set of desired hemodynamic outputs specified by the user, including:

Systolic aortic pressure, diastolic aortic pressure, heart rate, systolic left ventricular volume, diastolic left ventricular volume, systolic right ventricular volume, diastolic right ventricular volume

The software will set model parameters such that all other hemodynamic outputs not specified by the user will fall within realistic clinical ranges.  

 

Related conference presentations:

Automated Tuning of a Lumped Parameter Model for Simulating Resting Cardiovascular Physiology.

1) Summer Biomechanics, Bioengineering and Biotransport Conference, Cambridge, MD, June 20-23, 2022.

2) 9th World Congress of Biomechanics, Taipei, Taiwan, July 10-14, 2022.

 

Cardiovascular Modeling & Experimentation Research Laboratory, Clemson University  http://www.cmerl.com

 

Files

LPN_Protocol.zip

Files (443.6 kB)

Name Size Download all
md5:2ecd6b8d577cc77eb4eeddcda8213d23
443.6 kB Preview Download

Additional details

Funding

U.S. National Science Foundation