Published February 23, 2022 | Version Version 2

OpenFOAM cases of the paper "Development and validation of an open-source CFD model for the efficiency assessment of data centers"

  • 1. Design and Simulation Tech. Inc., 26480, Eskisehir, Turkey

Description

This dataset contains the underling data for the paper "Development and validation of an open-source CFD model for the efficiency assessment of data centers”, submitted for the consideration and open review in Open Research Europe (ORE).

Validation1.tar.xz: OpenFOAM files and scripts for the simulation of flow and thermal structures in an enclosed environment (Wang and Chen, 2009).

Wang, Miao; Chen, Qingyan (2009). Assessment of Various Turbulence Models for Transitional Flows in an Enclosed Environment (RP-1271). HVAC&R Research, 15(6), 1099–1119. doi:10.1080/10789669.2009.10390881

Validation2-kOmegaSSTModel.tar.xz: OpenFOAM files and scripts for the simulation of forced convection in a room (Zhang et al. 2007) using k-omega SST turbulence model. 

Zhao Zhang, Wei Zhang, Zhiqiang John Zhai & Qingyan Yan Chen (2007) Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature, HVAC&R Research, 13:6, 871-886, DOI: 10.1080/10789669.2007.10391460

Validation2-RNGkEpsilonModel.tar.xz: OpenFOAM files and scripts for the simulation of forced convection in a room (Zhang et al. 2007) using RNG k-epsilon turbulence model. 

Zhao Zhang, Wei Zhang, Zhiqiang John Zhai & Qingyan Yan Chen (2007) Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature, HVAC&R Research, 13:6, 871-886, DOI: 10.1080/10789669.2007.10391460

Validation3.tar.xz: OpenFOAM files and scripts for the simulation of strong natural convection in a model fire room (Murakami et al. 1995).

Murakami, S., S. Kato, and R. Yoshie. 1995. Measurement of turbulence statistics in a model fire room by LDV. ASHRAE Transactions 101(2):287–301.

Validation4.tar.xz: OpenFOAM files and scripts for the simulation of thermal distribution in an open-aisle data center (Abdelmaksoud et al. 2013).

W.A. Abdelmaksoud, T.Q. Dang, H. Ezzat Khalifa, R.R. Schmidt Improved computational fluid dynamics model for open-aisle air-cooled data center simulations J. Electron. Packag., 135 (2013), pp. 030901-30913

Results_Validation1.tar.xz: Simulation results of the Validation case 1.

Results_Validation2.tar.xz: Simulation results of the Validation case 2.

Results_Validation3.tar.xz: Simulation results of the Validation case 3.

Results_Validation4.tar.xz: Simulation results of the Validation case 4.

layout.csv: Input file for the Validation case 4.

Notes

This data was created in the scope of Work Package 2: Dynamic cooling design concept based on open source CFD model

Files

layout.csv

Files (4.0 MB)

Name Size
md5:097f8f6bb78dec4377c309891393a304
406 Bytes Preview Download
md5:4c036dffb7446cea318d33a3aa64b3c7
1.8 MB Download
md5:37a2ecc4dbc8d228c6c6ea574c56c809
419.0 kB Download
md5:6be2100a553b1da436ab196c29dfa1d1
130.1 kB Download
md5:56c0b14e0eb74d81e0c4a5fdf4b87f0e
1.6 MB Download
md5:1f4c0a31d04169cfd465d2625683a1a6
4.6 kB Download
md5:c542d477e2e5b608783525b811b817fe
3.7 kB Download
md5:1c440d0f00f5e654d3e26fd950ef0fb2
3.7 kB Download
md5:0f2c8c6da0f420adac56cd08da9bfebe
3.6 kB Download
md5:bb33e3edd34d6068deadd3f1cfc64bea
5.6 kB Download

Additional details

Funding

European Commission
ECO-Qube - Artificial-Intelligence-Augmented Cooling System for Small Data Centres 956059

References

  • Wang, Miao; Chen, Qingyan (2009). Assessment of Various Turbulence Models for Transitional Flows in an Enclosed Environment (RP-1271). HVAC&R Research, 15(6), 1099–1119. doi:10.1080/10789669.2009.10390881
  • Zhao Zhang, Wei Zhang, Zhiqiang John Zhai & Qingyan Yan Chen (2007) Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature, HVAC&R Research, 13:6, 871-886, DOI: 10.1080/10789669.2007.10391460
  • Murakami, S., S. Kato, and R. Yoshie. 1995. Measurement of turbulence statistics in a model fire room by LDV. ASHRAE Transactions 101(2):287–301.
  • W.A. Abdelmaksoud, T.Q. Dang, H. Ezzat Khalifa, R.R. Schmidt Improved computational fluid dynamics model for open-aisle air-cooled data center simulations J. Electron. Packag., 135 (2013), pp. 030901-30913