The Experimental Failure behaviour of a Prestressed Concrete Electricity Transmission Pole: A Case Study for Kannauj Soil, Uttar Pradesh, India
Authors/Creators
- 1. Assistant Professor, Department of Civil Engineering, D.D. University, Nadiad, Gujarat, India and (Former QIP Research Scholar, Department of Civil Engineering, IIT Kanpur, India.)
Description
Pre-stressed Cement concrete poles are widely used for supporting electricity supply lines throughout India. Its common observation that the poles fail under heavy wind as well as earthquakes. The response of the poles depends upon the strength of pole material, supporting soil, and depth of embedment of the pole. To economize the erection its general practice to erect the pole as the self-supporting pole. This paper investigates the behaviour of a prototype self-supporting electric pole for two different kinds of soil compaction material with respect to monotonic lateral load. Load versus displacement in loading and unloading is analysed for two different soil conditions. The geotechnical design considerations are suggested for the embedment of poles in soils.
Files
The Experimental Failure Behaviour -Formatted Paper.pdf
Additional details
References
- Cohen, E., & Perrin, H. (1957). Design of multi-level guyed towers: Wind loading. Journal of the Structural Division, 83(5), 1355-1.
- Odley, E. Analysis of high guyed towers. J. Struct. Div. ASCE 92 (1) (1966) 169–198.
- Gaylord, E. H. (1973). Design criteria for steel transmission poles.
- Chugh, A. K., & Biggers, S. B. (1978). Analysis of steel transmission pole structures. Computers & Structures, 8(1), 125-133.
- Vanderbilt, M. D., & Criswell, M. E. (1988). Reliability analysis of poletype transmission structures. Computers & structures, 28(3), 335-343.
- Dicleli, M. U. R. A. T. (1997). Computer-aided optimum design of steel tubular telescopic pole structures. Computers & structures, 62(6), 961-973.
- Kalkan, E., & Laefer, D. F. (2004). Seismic based strengthening of steel and RC telecommunication poles based on fem analysis. Engineering structures, 26(14), 2101-2111.
- Khalili, S. M. R., & Saboori, B. (2010). Transient dynamic analysis of tapered FRP composite transmission poles using finite element method. Composite structures, 92(2), 275-283.
- Saboori, B., & Khalili, S. M. R. (2011). Static analysis of tapered FRP transmission poles using finite element method. Finite Elements in Analysis and Design, 47(3), 247-255.
- Caracoglia, L., & Jones, N. P. (2007). Numerical and experimental study of vibration mitigation for highway light poles. Engineering structures, 29(5), 821-831.