Published May 19, 2021 | Version v2.0

GUV total ozone column and effective cloud transmittance from three Norwegian sites 1995-2019

Authors/Creators

  • 1. NILU - Norwegian Institute for Air Research

Description

Total ozone column (TOC) and effective cloud transmittance (eCLT) from GUV-511 in Oslo (Norway), GUV-541 from Andøya/Tromsø (Norway), and GUV-541 from Ny-Ålesund (Svalbard, Norway). Data are harmonized with respect to Brewer DS and SAOZ total ozone values at the sites. 

Responsible institute: NILU - Norwegian Institute for Air Research
Collaborative institute: Norwegian Radiation and Nuclear Safety Authority, DSA

Retrieval method described in: 
Dahlback, A. (1996), Measurements of biologically effective UV doses, total ozone abundances, and cloud effects with multichannel, moderate bandwidth filter instruments, Appl. Opt. 35, 6514–6521

1h average noon-time values, based on data with 1-minute time resolution.

TOC retrievals from 305/320 nm channel ratio
eCLT retrievals from 340 nm channel 

Calibrations based on the FARIN2005-campaign and annual site visits with a travelling reference GUV instrument from DSA (https://agupubs.onlinelibrary.wiley.com/doi/full/10.1029/2007JD009731)

Funding: NILU - Norwegian Institute for Air Research, Norwegian Environment Agency, Norwegian Ministry of health and Care Services

Files

GUV_Andoya.txt

Files (843.5 kB)

Name Size Download all
md5:0ec13af835d48a7f73485746143dbc08
280.9 kB Preview Download
md5:7ddf9da1d1b5a5633248e1e3fc88b4e2
288.3 kB Preview Download
md5:6c92c8568f982e38d9015333cb92a9a7
274.3 kB Preview Download